Pag. 68 / 70
DMAN802000093-Manual MB250 Hydro Wood-Pellet STD11
P80
Number of cleaning cycles for Cleaning Engine
0
100
[nr]
P81
Auger Management: 0=without encoder; 1=with encoder; 2=with
automatic encoder. If
P81
=1 the system works with encoder
management. In case of failed adjustment or signal lack, the system blocks
with Er47 and Er48 errors. If system blocks with Er47 error, resetting the
alarm the system can work again in
P81
=0 modality
0
2
[nr]
P86
Service Function management: 0=the system doesn’t go in Block state at
the end of
T66
, 1=the system goes in Block state at the end of
T66
0
1
[nr]
P96
Door Sensor management:
0
4
[nr]
Parameter Value
Exhaust Fan
Exhaust Fan 2
0
Off
Off
1
maximum speed
Off
2
Off
maximum speed
3
maximum speed
maximum speed
4
(
PA46
*
P30
)/100
(
PA47
* maximum speed)/100
PA18
Percentage Variation of the combustion fan speed if there is DHW request
-100
100
[%]
PA19
Percentage Variation of the Auger Speed/On time if there is DHW request
-100
100
[%]
PA23 T71
Timer and Door management in order to switch to Wood mode
0
1
[nr]
PA29
Power for transition to Wood in Combi 2 modality
0
6
[nr]
PA41
At the system ignition the default parameters for Auger and Combustion
Fan are used
0
1
[nr]
PA44
NTC probe type for input IN4: 0=NTC10K; 1=NTC231K
0
1
[nr]
PA46
Percentage to set the Combustion fan speed in case of open door and
P96
=4 (see
P96
)
0
100
[%]
PA47
Percentage to set the Combustion fan 2 speed in case of open door and
P96
=4 (see
P96
)
0
100
[%]
PA53
Loading Engine management in Night Mode: 0= normal operation; 1=Off
0
1
[nr]
PA54
Cleaning Engine management in Night Mode: 0= normal operation; 1=Off
0
1
[nr]
PA55
Cleaning Engine 2 management in Night Mode: 0= normal operation;
1=Off
0
1
[nr]
PA56
Brazier Cleaning Engine management in Night Mode: 0= normal operation;
1=Off
0
1
[nr]
PA62
Cleaning Engine cleaning cycles in brazier extinguishing phase
0
100
[nr]
PA63
Cleaning Engine cleaning cycles in Check up phase
0
100
[nr]
PA64
Cleaning Engine 2 cleaning cycles in brazier extinguishing phase
0
100
[nr]
PA65
Cleaning Engine 2 cleaning cycles in Check up phase
0
100
[nr]
TS01
Exhaust Probe Calibration Factor
-20
20
[%]
TS02
Water Boiler Probe Calibration Factor
-20
20
[%]
Primary Air Flow Sensor Menu
Menu to set the Air Flow Sensor parameters; it is visible only in Pellet modality, all combustion parameters
are referred to the current Recipe. It has 3 submenu:
1.
Enable
Code
Description
Min
Max
Unit
A24
Sensor management: 0=disabled; 1=Combustion Fan regulation;
2=Combustion Fan + Auger regulation; 3=Auger regulation; 4=Auger +
Combustion Fan regulation
0
4
[nr]
A25
Regulation error management: 0=the system does nothing; 1=regulator
resets and restarts regulation; 2=regulator disabled; 3=system in Block with
error Er17
0
3
[nr]
A31
Regulation Outputs management: 0= regulator goes back to the last output;
1= regulator always works on the last output
0
1
[nr]
T19
Waiting time for stabilization of regulation of first output
5
900
[s]
T20
Waiting time for stabilization of regulation of second output
10
900
[s]
T80
Waiting time for first regulation
0
900
[s]
V60
Combustion Fan Regulation Step
5
100
[V]
10
500 [RPM]
C60
Auger Regulation Step
0,1
20
[s]