Pag. 10 / 44
DMAN802000066-Manuale SY250 Idro 4/8 tasti
3
Control Panel
Setting the parameter
P50
it is possible to select the keyboard connected to the control board. If
P50
=0 is
selected the keyboard
CP110
(4 keys), if
P50
=1 is selected the keyboard
CP120
(8 keys).
ESC
G
S
W
L1
L5
L4
D2
D3
D1
P2
P1
P4
P3
L6
L7
L2
L3
CP110
ESC
L3
L2
L1
L8
L9
L10
L11
L4
D1
D2
D3
K1
K2
K3
K4
K8
K7
K6
K5
SET
DISP
G
S
W
L12
L13
L5
LL6
L7
CP120
-Buttons
CP110
Click
Long Pressure
P1
Visualisations / Exit Menu
Ignition / Extinguishing / Block reset
P2
Thermostat modify (+) / Increase data
Pellet loading correction
P3
Combustion Power modify / Save data
Manual pellet loading
P4
Thermostat modify (-) / Decrease data
Combustion Fan speed correction
CP120
Click
Long Pressure
K1
Exit Menu
Ignition / Extinguishing / Block reset
K2
Combustion Power modify (+)
-
K3
Thermostat modify (+) / Increase data
Pellet loading correction
K4
-
Enable Chrono time slot
K5
Input User Menu 2 / Save data
Manual pellet loading
K6
Combustion Power modify (-)
-
K7
Thermostat modify (-) / Decrease data
Combustion Fan speed correction
K8
Visualisations
Summer / Winter choice
-Leds
L1
Led On: Pump On
L2
Led On: Auger On
L3
Led On: Ignition Resistance On
L4
Led On: thermostat temperature reached
L5
G
Led On: Daily program seleceted
L6
S
Led On: Weekly program seleceted
L7
W
Led On: Week End program seleceted
L8
Led On: Valve On
L9
Led On: lack of pellet in the tank
L10
Led On: Summer functioning selected
L11
Led On: Winter functioning selected
L12
Led On: Safety Pellet Valve or Auger 2, or External Loading Pellet Engine, or Cleaning
Engine On (only for Output V2)
L13
Led On: there is a sanitary water demand (contact closed).
Only for hydraulic systems with flow switch
-Control Panel Configuration:
Pushing at the same time the buttons
P1
/
P3
or
K1
/
K5
it is possible to choose the keyboard connected
to the control board without enter in System Menu.
-Values shown on the main frame:
Display
D1
: Time, Functioning States, Errors, Menu, Submenu, Parameter value;
Display
D2
:
Power, Parameter code; Display
D3
: Main Temperature, Parameter code
-Functioning States:
Check Up (
CHEc
), Ignition (
On 1
,
On 2
,
On 3
,
On 4
), Stabilisation (
On 5
), Modulation (
Mod
), Standby
(
StBY
), Run Mode, Safety (
SAF/Erxx
), Extinguishing (
OFF
), Recover Ignition (
rEc
), Block (
Alt/Erxx
).