Pag. 11 / 44
DMAN802000066-SY250 Idro 4/8 Buttons Manual
-
Errors:
Er01
Error Safety High Voltage 1. Also with the system Off
Er02
Error Safety High Voltage 2. Only if the Combustion Fan is On.
Er03
Extinguishing for exhaust under temperature
Er04
Extinguishing for water over temperature
Er05
Extinguishing for exhaust over temperature
Er07
Encoder Error. This error can occurs for lack of Encoder signal
Er08
Encoder Error. This error can occurs in case of adjustment problems of rounds number
Er09
Water pressure low
Er10
Water pressure high
Er11
Real time clock error
Er12
Extinguishing for Ignition failed
Er15
Lack of voltage
Er17
Air Flow Regulator Error
Er18
Run out of pellet
Er39
Air Flow Regulator Sensor broken
Er41
Minimum air flow in Check Up not reached
Er42
Maximum air flow Up reached (
F40
)
-
Other messages:
Sond
Visualisation of the state of temperature probes. The message displayed in Check-Up
indicates that the red temperature on one or more probes is equal to the minimum value
(0°C) or maximum (it depend on probe considered). Check that the probes aren’t open (0°C)
or in short-circuit (maximum value of the temperature scale).
Hi
Boiler water temperature greater than 99 °C.
SErU
This message notifies that the planned hours of functioning (parameter
T66
) is reached. It is
necessary to call for service.
PULi
This message notifies that the planned hours of functioning (parameter
T67
) is reached. It is
necessary to clean the stove or boiler.
FLu
The message appears in Run Model and indicates that there is a sanitary water demand. (It
appears only for plumbing systems with a flow switch).
Ignition
Block
The message appears if the system is turned off during Ignition (after Preload) by an external
device: the system will stop only when it goes in Run Mode.
3.1
User Menu 1
-
Boiler Thermostat:
Menu which allows to modify the Boiler Thermostat’s value. It is possible to program the minimum and
the maximum value of the Boiler Thermostat setting the
Th26
and
Th27
Thermostats.
-
Visualisations:
tA
Control board room temperature (visible only if
A19
=1)
tP
Buffer temperature (visible only if
P26
=2, 3, 4)
tF
Exhaust temperature
UF
Combustion Fan speed [RPM/Volt]
FUnC
Funzionamento Modalità Summer (
ESt
)/Winter (
InU
)
FC
Firmware code and revision:
FYSD01000114.00.00
(product without 2Ways)
FYSD01000102.00.00
(product with 2Ways)
395
Product Code:
0Y.0X
-
Combustion Power Setting:
Click on
P3
or
K2/K6
button: the
D2
display blinks. With other click of the same button the power is
changed. Ex.: 1–2–3–4–5–A (A=Automatic combustion). After 5 seconds the new value is saved and the
display shows as normal.
-
Manual Pellet Loading:
The long pressure of button
P3
or
K5
activates the Pellet Manual Loading with activation of Auger
engine in continuous way. The bottom display shows the word
LoAd
, the up display shows the passed
loading time. To stop the loading push any button. The loading stops automatically after 300 seconds.
-Pellet Loading Correction:
The long pressure of
P2
or
K3
button activates this function. The bottom display shows
PELL
, the
upper display the value. With buttons
P2
/
P4
or
K3
/
K7
the value is increased or decreased. Values are