Pag. 16 / 44
DMAN802000066-SY250 Idro 4/8 Buttons Manual
U03
Power 1
0
230
[Volt]
300
2800 [RPM]
U04
Power 2
0
230
[Volt]
300
2800 [RPM]
U05
Power 3
0
230
[Volt]
300
2800 [RPM]
U06
Power 4
0
230
[Volt]
300
2800 [RPM]
U07
Power 5
0
230
[Volt]
300
2800 [RPM]
U08
Power 6
0
230
[Volt]
300
2800 [RPM]
U09
Periodic Cleaning Power
0
230
[Volt]
300
2800 [RPM]
U10
Second Ignition Power
0
230
[Volt]
300
2800 [RPM]
U11
Modulation Power
0
230
[Volt]
300
2800 [RPM]
P23
Extinguishing Power
0
230
[Volt]
300
2800 [RPM]
P14
Minimum Speed of Combustion Fan
0
230
[Volt]
300
2800 [RPM]
P30
Maximum Speed of Combustion Fan
0
230
[Volt]
300
2800 [RPM]
P16
Calibration step of Combustion Fan
1
20
[%]
P25
0
=Combustion Fan without Encoder;
1=
Combustion Fan with
Encoder;
2=
Combustion Fan with Encoder and automatic switch
to
P25
=0 if there is not encoder signal (alarm
Er07
)
0
2
[nr]
3.3.3
Heatingn Fan Menu (TP03)
Menu to set the Heating Fan parameters. Set these parameters if
P44
=6.
Code
Description
Min
Max
Unit
F01
Power 1
0
230
[Volt]
F02
Power 2
0
230
[Volt]
F03
Power 3
0
230
[Volt]
F04
Power 4
0
230
[Volt]
F05
Power 5
0
230
[Volt]
F06
Power 6
0
230
[Volt]
P06
Heating management:
1
=heating power is the same of
combustion power;
2
=heating power is proportional to the
exhaust temperature;
3
=heating power is proportional to the
room temperature
1
3
[nr]
3.3.4
Thermostats Menu (TP04)
Code
Description
Min
Max
Unit
Th01
Stove off
5
900
[°C]
Th02
Resistance switch off
5
900
[°C]
Th03
Pre-Extinguishing thermostat for low flue gas temperature
5
900
[°C]
Th05
Switch on Heating Fan Thermostat
5
900
[°C]
Th06
Thermostat to go in Stabilisation from Variable Ignition
5
900
[°C]
Th07
Exhaust Modulation
5
900
[°C]
Th08
Exhaust Safety
5
900
[°C]
Th09
Bypass Ignition
5
900
[°C]
Th18
Ice Thermostat
5
10
[°C]
Th19
Activation Pump Thermostat
30
85
[°C]
Ih19
Activation Pump Thermostat Histeresys
1
20
[°C]
Th20
Sanitary 1 Thermostat
30
85
[°C]
Th21
Sanitary 2 Thermostat
30
85
[°C]