Contains timer parameters, counters for the management of the selected plant
6.7
6.7
6.7
6.7
Functions
Functions
Functions
Functions
From the main menu select the function from the available
6.7.1
6.7.1
6.7.1
6.7.1
Bucket Charge
Bucket Charge
Bucket Charge
Bucket Charge
This function increases the collector’s temperature in conditions of low radiation. In case of differential
between the probes S1 and S2, but the temperatures S1 and S3 are both less than thermostat
THS301
, the
solar pump is managed with time
TIM001
(Pause) and
TIM002
(Work) to allow the increase of the solar
fluid temperature until the value
THS301
. The cycle Pause/Work is repeated for a number of time
COU000
,
then the function is deactivated for a time
TIM000
. In the end the function starts again in case of right
conditions.
N.B. In The systems with stratification, activating the Bucket Charge Function, the
stratification function is automatically deactivated.
DESCRIPTION
Code
Thermostat(on S3 under the function is activated
THS301
Thermostat hysteresis THS301
HYS301
Function deactivation time after COU00 pump’s stop
TIM000
Pump’s pause time during the function
TIM001
Pump’s work time during the function
TIM002
Maximum number of attempts of the pump during the function
COU000
Enable Function
ENA000
6.7.2
6.7.2
6.7.2
6.7.2
Holiday
Holiday
Holiday
Holiday
The function
Holiday
is for the setting up of the system during long periods of break.
When the function is activated the system does:
-
Boiler’s Cooling
-
Deactivation Boiler’s Integration
-
Boiler’s Cooling through the Solar Circuit
DESCRIPTION
Code
Thermostat on S2, over the System cools the boiler when there is negative differential S1-S2.
THS201
Thermostat hysteresis THS201
HYS201
Enable Holiday function
ENA002
6.7.3
6.7.3
6.7.3
6.7.3
De
De
De
De----Ice
Ice
Ice
Ice
Contains Thermostats/Hysteresis/Parameters of the De-Ice function. If temperature (S1) is less than
Thermostat
THS101
, the Solar Pump is activated in modality Pause / Work.
DESCRIPTION
Code
Under this thermostat the function is activated
THS101
Thermostat hysteresis THS102
HYS101
Pump’s work time during the function (sec)
TIM012
Pump’s time pause during the function (min)
TIM013
De-Ice function enable
ENA007
6.7.4
6.7.4
6.7.4
6.7.4
Stratification
Stratification
Stratification
Stratification
In case of differential S1-S3 the high boiler zone is charged up to THS306; then the low boiler zone is
charged up the thermostat THS300. In case of absence of differential S1-S3 but presence of differential
S1-S2, the lower boiler’s zone is charged in Pause/Work modality.
After a number of cycles
COU001
, the function is deactivated for a time
TIM017
.
N.B. In plants with stratification, activating the function Bucket Charge, the function
stratification is automatically deactivated and vice versa