Safety

When working with electricity, no instrument can guaran-
tee complete safety. It is the responsibility of the person
who works with the instrument to operate it in a safe way.
Maximum security is achieved by selecting the proper in-
struments and following safe working procedures.

Safe

working tips are given below:

Always work according (local) regulations.

Work on installations with voltages higher than 25 V AC or
60 V DC should only be performed by qualified personnel.

Avoid working alone.

Observe all indications on the Current Clamp TP-CC400 be-
fore connecting any wiring

The Current Clamp TP-CC400 complies with class II, over-
voltage CAT II - 600 V of the EN 61010-1 and EN 61010-2-032
standards. Do not clamp around conductors with voltages
equal to or exceeding 300 V DC or 240 Vrms AC.

To avoid physical injury, measurements on bare conductors
or conductors with damaged insulation are not allowed

Check the Current Clamp TP-CC400 and test leads for dam-
ages. Do

not

use them if they are damaged

Take care when measuring at voltages higher than 25V AC
or 60 V DC.

Do not operate the equipment in an explosive atmosphere or
in the presence of flammable gases or fumes.

The Current Clamp TP-CC400 is designed for indoor use
only

Do not use the Current Clamp TP-CC400 if it does not op-
erate properly. Have the equipment inspected by qualified
service personal. If necessary, return the Current Clamp TP-
CC400 to TiePie engineering for service and repair to ensure
that safety features are maintained.

If the Current Clamp TP-CC400 is used in a manner not
specified, the protection provided by the instrument may be
impaired.

2

Current Clamp TP-CC400

Summary of Contents for TP-CC400

Page 1: ...Current Clamp TP CC400 User s manual Revision 1 2...

Page 2: ...nductors with voltages equal to or exceeding 300 V DC or 240 Vrms AC To avoid physical injury measurements on bare conductors or conductors with damaged insulation are not allowed Check the Current Cl...

Page 3: ...C400 for which this declaration is valid is in compliance with EN 55011 2009 A1 2010 EN 61000 6 1 2007 EN 55022 2006 A1 2007 EN 61000 6 3 2007 according the conditions of the EMC standard 2004 108 EC...

Page 4: ...ton This buton sets the current readout to zero This function is also used when measuring DC current to remove an offset value caused by residual magnetism in the core of the jaw 5 Power ON OFF led 6...

Page 5: ...from the underside to the upside of the clamp 6 Read the measured voltage value and convert it to the corre sponding current value 40 A range 10 mV equals 1 A 400 A range 10 mV equals 10 A AC current...

Page 6: ...test leads from the Current Clamp TP CC400 2 Remove the screw from the battery compartment at the back of the Current Clamp TP CC400 3 Remove the old battery 4 Insert a new 9 V NEDA 1604 IEC 6F22 bat...

Page 7: ...attery Operating environment 0 C to 50 C 70 RH Storage environment 20 C to 70 C 80 RH Compliances CE Yes ROHS Yes Accuracy At 23 C 5 C 70 RH maximum DC 40 A range 0 A to 20 A 3 5 6 digits 20 A to 40 A...

Page 8: ...8601 WL Sneek The Netherlands Tel 31 515 415 416 Fax 31 515 418 819 E mail sales tiepie nl www tiepie com This information is subject to change without notice Copyright c 2017 TiePie engineering All r...

Reviews: