background image

Current Clamp TP-CC80

User’s manual

Revision 1.3

Summary of Contents for TP-CC80

Page 1: ...Current Clamp TP CC80 User s manual Revision 1 3...

Page 2: ...conductors with voltages equal to or exceeding 300 V DC or 240 Vrms AC To avoid physical injury measurements on bare conductors or conductors with damaged insulation are not allowed Check the Current...

Page 3: ...80 for which this declaration is valid is in compliance with EN 55011 2009 A1 2010 EN 61000 6 1 2007 EN 55022 2006 A1 2007 EN 61000 6 3 2007 according the conditions of the EMC standard 2004 108 EC al...

Page 4: ...on This buton sets the current readout to zero This function is also used when measuring DC current to remove an o set value caused by residual mag netism in the core of the jaw 5 Power ON OFF led 6 L...

Page 5: ...om the upside to the underside of the clamp 6 Read the measured voltage value and convert it to the corresponding cur rent value 20 A range 100 mV equals 1 A 80 A range 100 mV equals 10 A AC current m...

Page 6: ...e test leads from the Current Clamp TP CC80 2 Remove the screw from the battery compartment at the back of the Current Clamp TP CC80 3 Remove the old battery 4 Insert a new 9 V NEDA 1604 IEC 6F22 batt...

Page 7: ...ronment 20 C to 70 C 80 RH Compliances CE Yes ROHS Yes Accuracy At 23 C 5 C 70 RH maximum DC 20 A range 3 5 mA DC 80 A range 100 mA to 40 A 3 0 3 A 40 A to 80 A 8 0 3 A AC 20 A range 10 mA to 10 A 40...

Page 8: ...7 8601 WL Sneek The Netherlands Tel 31 515 415 416 Fax 31 515 418 819 E mail sales tiepie nl www tiepie com This information is subject to change without notice Copyright 2018 TiePie engineering All r...