Using a Remote Unit
01-0868-401B 12/02
33
MC CLOCK TIME
hh:mm:ss
—
Sets the current time in the format:
hh:mm:ss
where:
■
hh
= hours, in a 24-hour format, from 00 to 23, where 00 is midnight
and
23 is 11 PM
■
mm
= minutes from 00 to 59
■
ss
= seconds from 00 to 59
For example, for 8 AM you would set 8, and for 8 PM you would set 20.
Both minutes and seconds can be set from 0 to 59.
Front panel equivalent: Control>Clock>Time
MC FLASH LIST
DVB, User0, User1, User2
—
Query-only, displays the currently active configuration.
Front panel equivalent: none
MC FLASH SAVE
<
string
>
User0, User1, User2
—
Saves current configuration with the label specified in <
string
>. If no
string is specified, the current configuration is saved as the power-up
configuration.
Front panel equivalent: Control>Configs>Save
MC FLASH <
string
>
DVB, User0, User1, User2
—
Resets the TDR60 with the specified default operating configuration.
Front panel equivalent: Control>Configs>Restore
MC RS232 BAUD
1200, 2400, 4800, 9600,
19200, 38400
9600
Sets the baud rate for the remote port.
Front panel equivalent: Control>RS232>Baud
MC RS232 DATA
7, 8
8
Sets the data bits for the remote port.
Front panel equivalent: Control>RS232>Data Bits
MC RS232 FLOW
SOFT, HARD
Hard
Sets the flow control of the RS-232 remote port to:
■
Software XON/XOFF
■
Hardware RTS/CTS
Front panel equivalent: Control>RS232>Flow Control
MC RS232 PARITY
None, Odd, Even
None
Sets the parity for the remote port.
Front panel equivalent: Control>RS232>Parity
MC RS232 STOP
1, 1.5, 2
1
Sets the stop bits for the remote port.
Front panel equivalent: Control>RS232>Stop Bits
PGCA
In_the_Clear, Scrambled
—
Query-only; displays whether or not the signal is PGCA protected.
Front panel equivalent: PGCA>Status
PGCA
AUTHORIZATION
Yes, No, N/A
—
Query-only; displays whether the originator of the service has
authorized your TDR60 to receive the selected service.
Note
:This command is only applicable when the received service is
scrambled.
Front panel equivalent: PGCA>Authorization
PGCA TIMEOUT
Time in seconds
—
Query-only; displays the amount of time that the service originator
allows the TDR60 to remain authorized to receive the selected service
in the event that the TDR60 stops receiving periodic service
authorization messages.
Note
:This command is only applicable when the received service is
scrambled.
Front panel equivalent: PGCA>Timeout on loss
QD
—
—
When QD is entered, the TDR60 returns the following information:
QPSK Demodulator:
RF Frequency: 11274 Mhz
LO Frequency: 10000 Mhz
Data Rate:
5500000 bps
Symbol Rate:
3978723 bps
Code Rate:
3/4
LNB Power:
OFF
Eb/No:
21.50 dB
Front panel equivalent: None
QD ACQR
1000 to 10000
2000
Sets the acquisition range.
Front panel equivalent: none
QD CR
1/2, 2/3, 3/4, 5/6, 7/8
5/6
Sets the Viterbi code rate of the demodulator.
Note
: This command is only applicable when Inp Type is set to
Demod.
Front panel equivalent: Input>Config>Code Rate
QD DR
1000000 to 48400000
8448000
Sets the data rate of the transport data stream of the demodulator.
Note
: This command is only applicable when Inp Type is set to
Demod.
Front panel equivalent: Input>Config>DatRate
Remote Command
Mnemonic
Parameter Range
Factory DVB
Default
Description