Using a Remote Unit
57
MUX CM
SCPC, MCPC,
Redund
SCPC
Defines the system as SCPC, MCPC, or redundant. Parameters are:
!
SCPC = single channel per carrier, disables multiplexing of
incoming external transport stream; outputs only local program
elements.
!
MCPC = multiple channels per carrier; enables the multiplexing of
an incoming external transport stream with local program
elements. MCPC allows the internal transport stream rate and the
output transport stream rate to be independently defined; these
parameters are not automatically calculated and set by the TE3000
in MCPC mode.
!
Redund = places the TE3000 in a redundant state; used when a
system is operating in a redundant, or protected, setup. When
Redund is selected, also set MUX RED_STATE.
Front panel command equivalent: Config>Tx Strm>Mode
MUX EXT_ENABLE
Off, On
On
Setting determines if the external transport stream is processed or
discarded. MUX EXT_Enable works in conjunction with the MUX CM
command. Parameters are:
!
On = transport stream is processed; MUX CM must be set to
MCPC or Redund
!
Off = transport stream is discarded; MUX CM must be set to SCPC
Front panel command equivalent: Config>Tx Strm>Ext TS Enable
MUX EXT_CNT
—
—
Displays the number of external services in the externally input
transport stream.
Front panel command equivalent: none
MUX EXT_LIST
—
—
Displays the list of active services being received on the external input
transport stream.
Front panel command equivalent: none
MUX EXT_RATE
—
—
Displays the measured external input transport rate in bps.
Front panel command equivalent: Config>Tx Strm>ExtRate
MUX EXT_STATUS
—
—
Displays the status of the externally-supplied transport stream.
Responses are: Absent = no signal, Unlocked = signal present, but no
transport lock, Locked = transport lock detected.
Front panel command equivalent: Config>Tx Strm>Ext TS Status
MUX LOC_ENABLE
On, Off
On
Setting determines whether or not the locally generated input is
included in the transport stream.
Front panel command equivalent: Config>Tx Strm>Loc TS Enable
MUX LOC_RATE
1000000 to 70000000
bps
8448000
Sets the local transport stream rate (generated internally by the
TE3000) in bits/second.
Front panel command equivalent: Config>Tx Strm>LocRate
MUX LOC_STATUS
—
—
Displays the status of the local input transport stream. Responses are:
Absent = no signal; Unlocked = signal present, but no transport lock;
Locked = transport lock detected.
Front panel command equivalent: Config>Tx Strm>Loc TS Status
MUX OUT_RATE
If SCPC= 1000000 to
70000000
If MCPC = 1000000 to
160000000
8448000
Sets the output transport stream rate. Range is dependent upon MUX
CM setting.
Front panel command equivalent: Config>Output>Data Rate
TE3000 Remote Command Descriptions
(continued)
Remote Command
Parameter Range
Factory
Default
Description
Summary of Contents for TE3000
Page 10: ...viii Preface ...
Page 14: ...4 TE3000 Overview ...
Page 52: ...42 Using the Front Panel ...
Page 94: ...84 Maintenance and Software Upgrades ...
Page 96: ...86 Technical Specifications ...
Page 102: ...92 TE3000 PID Assignments ...
Page 112: ...102 Glossary ...