Edition
Manual
Chapter
Page
2008-10-23 Workshop Manual, Stiga Titan 4 Hydraulic system
36
4.7.2 Hydraulic oil level indicator
There must be oil inside the lower sight glass
(B).
There must not be any oil inside the upper sight
glass.
If the oil level is too high there is a risk of oil
flowing out through the bleed valve. If the oil
level is too low there is a risk of an increase in
the oil temperature and damage to the
hydraulic system.
4.7.3 Disassembly the hydraulic
pumps
Disassembly the hydraulic pumps as follows:
1. Drain the hydraulic oil. See above.
2. Dismantle the cruise control device, fitted to
the hydraulic pumps. See section 2.
3. Remove the hydraulic pump belts. See sec-
tion 5.
4. Remove the pump pulley by holding it with a
big polygrip or similar while loosening the axle
nut. Use a 19 mm spanner.
5. Loosen the brake bracket by unscrewing the
two nuts.
6. Bend the bracket together with the throttle
wire away from the working area. If neces-
sary, lock it in place with a lacing wire or simi-
lar.
A
C
B