7.1 Description
The electrical components are connected with cables, integrated in two complete insulated
harnesses, one front harness and one rear harness. The harnesses are connected at the
articulating point with three 9-pole connector sockets. Thus the cables are protected
against wear, contaminations and other stresses. The cables are connected to the actual
components with tab or screw connectors and in some cases with multi-contact connectors.
The electrical system contains several safety circuits. Therefore actual levers and pedals
are provided with micro switches. The micro switches are shown in the figure below. The
signals from the micro switches are used to interlock the actual circuit in case of a forbidden
manoeuvre attempt. Some manual switches and relays have also built in interlocks, related
to the safety system.
The wiring diagrams are presented separately in the respective spare parts manual. To
achieve a complete understanding of the electrical system for a certain machine, read also
the actual wiring diagram.
All current consumption circuits except the start circuit are protected by fuses.
See also ““Repair and replacements” at page 11.
Micro switch PTO control
Micro switch under the seat
Micro switch at the
brake pedal lever
Relays and motor
control unit
by implement lift lever
Fuses