If the GFCI fails to operate in this manner, your spa may have an electrical malfunction, and you may be risking electrical shock. Turn off all circuits
and do not use the spa until the problem has been corrected by an authorized service agent.
WARNING:
Removal of the GFCI from the spa’s power cord will result in an unsafe spa and will void the spa’s warranty.
IMPORTANT:
Should you ever find the need to move or relocate your Tiger River
®
spa, it is essential that you understand and apply these
installation requirements. Your Tiger River spa has been carefully engineered to provide maximum safety against electric shock. Remember,
connecting the spa to an improperly wired circuit will negate many of its safety features.
NOTE:
Long wiring runs may require larger-gauge wire than stated. We recommend using a maximum 3% voltage drop when calculating wire
gauge requirements.
OPERATINg INSTRUCTIONS
Tiger River spas are manufactured in two different electrical versions, 230 volt permanently connected, and 115 / 230 volt convertible models. The
Caspian
™
and Bengal
®
(Model MM) spas are available only as 230 volt permanently connected models, and use a continuous heating system.
This means that the heater may turn on while the jet pump is operating, unlike 115 volt models where the heater will automatically be turned off
when the the jet pump is turned on.
The remaining spa models, the Bengal (Model M) and Sumatran
®
, are available as 115v / 230v convertible systems, meaning that a 115 volt
model can be converted to a 230 volt model. The benefit of operating in 230 volt mode is an increase in the wattage (heater capacity) of the heater,
allowing the heater to run when the jet pump is operating, which keeps your water hotter longer when the jets are in use. Contact your authorized
Tiger River dealer for the requirements to convert between electrical systems at your home.
IMPORTANT:
Improper conversion from one system to another may damage the spa’s electrical components. Always consult your authorized
Tiger River dealer prior to converting from one electrical system to another.
230 vOLT peRManenTLy COnneCTed MOdeL
•
CaSpIan (MOdeL Chp)
•
bengaL (MOdeL MM)
The 230 volt permanently connected Caspian & Bengal (Model MM) comes with a subpanel which contains two GFCI circuit breakers - a 20 amp /
30 amp / 230 volt GFCI circuit breaker system. The subpanel and spa must be “hardwired” by a licensed electrician using appropriate wire, conduit,
and fittings.
The Caspian model features one Wavemaster
®
8000 (2 hp single speed) jet pump and one Wavemaster 8200 (2 hp two speed) jet pump. The
Bengal (Model MM) features a Wavemaster 9200 (2½ hp two speed) jet pump. The Caspian and Bengal (Model MM) spas have a No-Fault
®
titanium, high watt density heater.The heating system consists of a 4,000 watt (4 kW) heater on the Caspian while the Bengal (Model MM) has a
6000 Watts (6kW) heater. The spas are also equipped with an energy efficient low-flow circulation pump, and a high-limit thermostat for protection
of user and equipment.
The heater will turn on while the jet pump is operating (after a 1½ degree temperature drop) to help maintain the water temperature during spa
use. Factors such as the number of people using the spa, the air temperature, and the length of time the pump is operated will affect the heating
system’s ability to maintain the water temperature.
115/230 vOLT COnveRTIbLe MOdeLS
•
bengaL (MOdeL M)
•
SUMaTRan (MOdeL n)
The 115 / 230 volt convertible Tiger River spa models come configured with a familiar 115 volt electrical system, with a GFCI plug at the end of a
cord. The GFCI plug contains a GFCI breaker for user and equipment protection. The 115 volt configuration requires a dedicated outlet to supply
power to the spa.
These models can be converted to 230 volt operation with the addition of a subpanel and a control box wiring change. Consult your dealer before
attempting to convert from 115 volt operation to 230 volt operation. Any damage to the spa from improper conversion is not covered under the warranty.
In the 115 volt configuration, either the heater, or the jet pump can operate, but they can’t work at the same time. In a 115 volt system, as long as
the jet pump is activated, the heater will not turn on. On the other hand, when the spa is converted to operate in the 230 volt configuration, the
heater and jet pump can operate simultaneously.
Each convertible spa model is equipped with a No-Fault
®
titanium, high watt density heater. The heater will operate at 1500 watts when the spa is
configured as a 115 volt cord-and-plug connected model, and at 6000 watts when the spa is configured as a 230 volt converted model. The heating
system consists of the No-Fault heater, an energy efficient low-flow circulation pump, and a high-limit thermostat and integrated pressure switch for
user and equipment protection.
The Bengal
®
(Model M) and the Sumatran
®
models use the Wavemaster
®
7000 (1.65 hp single speed) jet pump to operate their jet systems. Both
feature the Silent Flo 5000
®
circulation pump, which will run continuously (even when the jet pump is operating) as part of the 24-hour continuous
filtration system.