1. Modules with TS4-A-2F add-on
2. RSS Transmitter and RSS Core (integrated in CPS 25/50/60kW inverter
Tigo RSD wire-boxes)
3. Inverter
SYSTEM OVERVIEW: TS4-A-2F
8
The TS4-A-2F requires a Tigo RSS Transmitter or inverter with built-in transmitter
for operation.
•
TS4-A-F mounting is recommended on the upper right as shown, but can be
placed elsewhere on the frame or bolted to the racking if needed.
•
TS4-A-F cable glands must not be facing up.
•
Allow clearance between PV module and mounting surface for air
circulation around TS4-A-F.
•
For installation on frameless modules, remove metal clips and bolt TS4-A to
rail. Do not drill additional mounting holes in the frame or metal bracket.
Note: connect modules to TS4-A inputs before connecting outputs
Rapid
Shutdown
System
Transmitter
1
2
3
Tigo Rapid Shutdown
DO NOT DISCONNECT
UNDER LOAD
NEC 690.12-2017 and C22.1-2015 Rule 64.218
4 - 123A
TS4-A-2F