IMPORTANT SAFETY INSTRUCTIONS

LETHAL VOLTAGE MAY BE PRESENT IN ANY PV INSTALLATION  

SAVE THESEINSTRUCTIONS

This manual contains important instructions for installation a n d maintenance of the Tigo

product models TS4-L, TS4-O, TS4-S, TS4-M, TS4-A-O, TS4-A-O-Duo, TS4-R-O, TS4-R-S, TS4-R-M,

TS4-R-O-Duo, TS4-R-S-Duo, TS4-R-M-Duo, Tigo Access Point (TAP), Cloud Connect

A d va n ce d (CCA), a n d related Tigo software a n d mobile applications.

Risk of electric shock, d o not remove cover, disassemble, or repair, no user serviceable

parts inside. Refer servicing to qualified service personnel.

Before installing or using the Tigo System, please read all instructions a n d warning

markings on the Tigo products, appropriate sections

of your inverter manual,

photovoltaic (PV) module installation manual, a n d other available safety guides.

Failure to adhere to these instructions m ay result in injury or death, d a m a g e to the

system, or voiding the factory warranty.

To reduce risk of fire a n d shock hazard, install this device with strict adherence to

National Electric C o d e (NEC) ANSI/NFPA 70 and/or local electrical codes. When the

photovoltaic array is exposed to light, it supplies a DC voltage to the Tigo TS4 units. The

TS4units start in the “ O N ” state a n d their output voltage m ay b e as high as the PV

module open circuit voltage (V

OC

) when co n n e cte d to the module. The installer should

use the same caution when handling electrical cables from a PV module with or without

the TS4units attached.

Installation must b e performed by trained professionals only. Tigo does not assume

liability for loss or d a m a g e resulting from improper handling, installation, or misuse of

products.

Remove all metallic jewelry prior to installing the Tigo TS4 units to reduce the risk of

contacting live circuitry. Do not attem pt to install in inclement weather.

Do not operate the Tigo TS4 units if they have b e e n physically d a m a g e d . Check existing

cables a n d connectors, ensuring they are in g o o d condition a n d appropriate in rating.

Do not operate Tigo TS4 units with d a m a g e d or substandard wiring or connectors. Tigo

TS4 units must b e mounted on the high e n d of the PV module backsheet or racking

system, a n d in any case a b o ve ground.

Do not connect or disconnect under load. Turning off the Inverter and/or the Tigo

products m ay not reduce this risk. Internal capacitors within the inverter c a n remain

charged for several minutes after disconnecting all power sources. Verify capacitors

have discharged by measuring voltage across inverter terminals prior to disconnecting

wiring if service is required. Wait 30 seconds after shutdown activation before

disconnecting DC cables or turning off DC disconnect.

Always assume TS4 units are in “ O N ” state, or m ay turn on when restarting.

The CCA must b e on the same AC branch circuit as the inverter to meet shutdown

requirements.