TAP PLACEMENT - LEGACY (PRE-MESH)
41
TAP attaches to module frame using
built-in bracket. Mounting holes are also
available in case of frameless modules.
Place TAP near center of array or each
sub-array.
Connect multiple TAP units in series and leave terminating resistor in final TAP only.
Use 4-conductor RS485 (18-22 AWG) cable between TAP and CCA.
access point
access point
access point
PWR
PWR
DATA
DATA
Quick connectors:
press wire into terminal
OR
Connector blocks:
use screw terminals
Remove resistor to connect
another Access Point in series.
- + B A
IN
OUT
B
B
A
A
PWR
DATA
B A
B A
B A
B A
AUX
RS485-1
RS485-2
GATEWAY
POWER
access point
50ft (15m)
Legacy configuration (same as Gateway):
• 120 TS4 units per TAP
• 360 TS4 units per CCA
• 7 TAPs per CCA
• 50ft (15m) radius with line of sight between TAP & all TS4 units