TDFM-136B Operating Instructions
08RE399
Edit Keys
step up through available operating modes (w, n, D)
step down through available operating modes (w, n, D)
accept the entry and exit
abandon the entry and exit
Table 3-2 Transceiver Operating Modes
Operating Mode
Bandwidth
Indicator
Analog Wide
25 kHz
'
w
'
Analog Narrow
12.5 kHz
'
n
'
P25 Digital
12.5 kHz
'
D
'
Note:
If an Operating Mode is selected that is incompatible with the current Squelch Mode, then
the Squelch mode will automatically be changed to one that is acceptable for that
Operating Mode (ie
>
x' for analog, 'm' for Digital Rx and 'g' for Digital Tx).
3.1.4
Scroll Backwards through Available Memories
Level 1
Key
Scope: Main only
Press and hold the back arrow (4) key to scroll the memories for the Main Channel BACK, or
down, through the programmed memories until reaching the lowest memory programmed, it will
then wrap around and restart from the top. Once the user releases the button the displayed
characteristics will be programmed. The scroll speed will increase as the button is held.
3.1.5
Start/Stop Scan
Level 1
Key
Scope: Main
only
This command allows the user to start and stop Scan operation, the system will scan the channels
that are in the same scan list that the currently displayed Main channel is a member of. Note that
the channels in the scan list must have scan enabled (see command L2-5) to be scanned. If the
scan has not been enabled for the memory, then the following screen appears:
Figure 3-3. Trying to start scan on a Channel with Scan disabled
If the channel has been enabled for scan the user will see the following screen:
Figure 3-4. Start scan on a Channel with Scan enabled
Once scan has started the scan list digit flashes to indicate that the unit is in SCAN mode. Also
note that the key level indicator position has the lock symbol, this indicates that all keypad keys are
disabled except for:
Technisonic Industries Ltd.
29
001Main D136.0000Rg
Error Non-Scanned Chan
001Main D136.0000Rg
GD1§Guard1 n154.0000Rt