TDFM-136B Operating Instructions
Edit Keys
Stop scan
change display brightness
Front panel switch operation is modified as well: operation of
MN/GD
or
G1/G2
will terminate scan
and restore normal operation of keys and switches. The front panel
Squelch
button is disabled.
The
HI/LO
power switch is unaffected.
3.1.6
Scroll Forewards through Available Memories
Level 1
Key
Scope: Main only
Press and hold the forward arrow (6) key to scroll the Main Channel FOREWARD, or up, through
the programmed memories until reaching the highest memory programmed, it will then wrap
around and restart from the bottom. Once the user releases the button the displayed
characteristics will be programmed. The scroll speed will increase as the button is held.
3.1.7
Edit Channel Operating Frequency
Level 1
Key
Scope: Main and Guard
This command allows the user to edit the
Operating Frequency
of the selected channel. The
frequency will be edited in duplex mode: first Receive, then Transmit. Once the receive parameter
is entered, the 2
nd
last character in the display will switch from “R” to “T”, the user can now enter
the transmit value. Note that the receive value is automatically entered, so to get simplex
operation, simply accept this entry. The edit screen appears as follows:
Figure 3-5. The User Screen to Edit the Main
frequency
Upon start, the cursor appears at the second character in the Frequency field of the channel to be
edited. The user may now enter the desired operating frequency as follows:
Edit Keys
to
decimal mode: enter number, cursor automatically advances
accept the entry and continue
abandon the entry and exit
The editor will not accept a value outside the limits of 136.0000 MHz. to 174.0000 MHz. In addition
frequency selection is limited to 2.5 kHz increments and valid 6.25 kHz frequencies in all
Operating modes (see appendix N for valid 6.25kHz frequencies).
30
Technisonic Industries Ltd
001 Main w136.0000Rx
Edit Frequency (0-9,#*)