Engine Key Positions: 

Off: 

Key  should  be  in  the  OFF  position  when  generator  is  not  in  use.    Key  may  also  be 
turned to the off position to stop the engine.  

ON: 

Key  should  be  in  the  ON  positions  while  engine  is  running  or  prior  to  starting  the 
engine with the remote or recoil starter. 

 

START:

  Turn key to start position to start the engine.   

 

 

Do not turn the key switch to START position when the engine is running.  
Doing so may damage the starting motor.  
 
Do not leave key in the ignition unattended. 
 

 
For starting instructions, see STARTING THE GENERATOR on page 18. 
 

Recoil Starter:  

The recoil starter may be used to start the engine instead of the key or remote start or if the battery 
is  discharged.    To  start  the  engine,  pull  the  starter  grip  lightly  until  resistance  is  felt,  then  pull 
briskly.  Repeat as necessary to start.  See STARTING THE GENERATOR on page 16 for more 
information. 
 

 

Do  not  allow  the  recoil  starter  handle  to  snap  back  against  the  engine. 
Return it gently to prevent damage to the starter.  
 
When  starting  the  engine  by  recoil  starter,  set  the  key  switch  to  the  ON 
position and pull the recoil starter handle. 
 

 

Fuel Valve: 

The fuel valve is located between the fuel tank and carburetor. When the 
lever is in the off (horizontal) position, the valve is closed and fuel will not 
flow from the gas tank to the engine.  
 
When  the  valve  lever  is  turned  to  the  ON  (vertical)  position,  fuel  is 
allowed to flow from the fuel tank to the carburetor.  
 
Be sure to return the fuel valve lever to the OFF position after stopping the 
engine.  

 
Choke Lever: 

The  choke  is  used  to  help  start  a  cold  engine.    The  choke 
shutter reduces the amount of air being mixed with fuel, thus 
providing  an  enriched  fuel  mixture  which  combusts  more 
easily.  The  choke  is  designed  to  operate  automatically  with 
the  remote  starting  feature,  but  must  be  opened  and  closed 
manually  when  using  the  key  or  recoil  start.    The  choke  is 
closed for starting when the large rectangular portion of the 
choke lever is rotated as far as it will easily go toward in a 
counter-clockwise direction (toward the air filter).  Once the 

Shown 

off 

Summary of Contents for TPP-4500G-A

Page 1: ...ow all safety rules and instructions in this manual before attempting to operate this machine Failure to comply with these instructions may result in personal injury Diagrams within this manual may no...

Page 2: ...HE GENERATOR 18 STOPPING THE GENERATOR 19 OPERATION INSTRUCTIONS 20 MAINTENANCE 22 STORAGE 25 INSTALLATION 26 TROUBLESHOOTING 27 WIRING DIAGRAM 29 MODEL SPECIFICATIONS 29 The engine exhaust from this...

Page 3: ...s injury Read them carefully Please read the manual and pay attention to these sections Save These Important Safety Instructions Read and understand all of these safety instructions Be sure to retain...

Page 4: ...HEN USING AIR TOOLS BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY Specific Warnings Carbon Monoxide When this tool is running ensure that the area is well ve...

Page 5: ...MMABE MATERIALS NEAR THE GENERATOR Do not smoke or allow sparks flames or other sources of ignition around the engine and fuel tank Fuel vapors are explosive Keep grounded conductive objects such as t...

Page 6: ...void body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded Do not abuse the power cord for your too...

Page 7: ...ERATE THE GENERATOR WITH WET HANDS Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground Do not touch electrically energized parts of the generator...

Page 8: ...s Loose clothes jewelry or long hair can be caught in moving parts Avoid accidental starting Make sure the power switch is in its OFF position and disconnect the spark plug wire when not in use Remove...

Page 9: ...your model Accessories that may be suitable for one generator may become hazardous when used on another generator Servicing Maintain labels and nameplates on the generator and engine These carry impor...

Page 10: ...exhaust fumes must be within legal limits and installation must always meet local building codes If the generator is installed outdoors it must be weatherproofed and should be soundproofed It should n...

Page 11: ...loose clothing and jewelry away from moving parts Be aware that when engine parts are moving fast they cannot be seen clearly Keep access doors on enclosures closed and locked when access is not requ...

Page 12: ...ich could result in electrocution Do not connect to a building electrical system unless a qualified electrician has installed an isolation switch Fire and Burn Hazards The exhaust system gets hot enou...

Page 13: ...13 GENERATOR COMPONENTS See next page for further explanations...

Page 14: ...engine Return it gently to prevent damage to the starter When starting the engine by recoil starter set the key switch to the ON position and pull the recoil starter handle Fuel Valve The fuel valve...

Page 15: ...ne damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically stop the engine the engine...

Page 16: ...HP 800 1300 Kitchen Microwave Oven 1000 watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500...

Page 17: ...pstick and then screw the dipstick back into the oil fill hole FILL OIL ON A LEVEL SURFACE Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped o Remove the...

Page 18: ...d keep heat sparks and flame away from the gasoline and engine Refuel only outdoors Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified...

Page 19: ...e switch to return to the ON position Operating the starter motor for more than 5 seconds can damage the motor o Recoil start Pull the starter grip lightly until resistance is felt then pull briskly D...

Page 20: ...ave a system ground that connects generator frame components to the ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire AC Applications Before conne...

Page 21: ...lly shut down In this case wait a few minutes and then reset the circuitry system by turning the circuit breaker to its on position Restart the generator and continue powering the remaining tools and...

Page 22: ...nomical and trouble free operation It will also help reduce air pollution Improper maintenance or failure to correct a problem before operation can cause a malfunction in which you can be seriously in...

Page 23: ...djust Combustion Chamber Clean After every 500 hours Fuel tank and filter Clean Fuel Tube Check Every 2 years replace if necessary 1 Service more frequently when used in dusty areas 2 For commercial u...

Page 24: ...f the engine has not been running for a long time the sediment cup should be cleaned Turn the fuel valve to the OFF position Remove the sediment cup O ring and filter Clean the sediment cup O ring and...

Page 25: ...rrester Use a brush to remove carbon deposits from the spark arrester screen Inspect the screen for breaks or tears and replace it if necessary Install the spark arrester in the reverse order of remov...

Page 26: ...bute the oil evenly in the cylinder Reinstall the spark plug Change the engine oil After removal from storage drain the stored gasoline into a suitable container and fill the generator tank with fresh...

Page 27: ...o the concrete slab using 3 8 diameter expansion anchor bolts not supplied Connect a 6 AWG grounding wire not included from the ground connector 8 on the generator to a grounding rod not included that...

Page 28: ...fully close the choke Spark plug damaged Readjust gap and dry the spark plug Replace if necessary Carburetor dirty Clean the fuel sediment cup Replace or service the carburetor No electricity to the A...

Page 29: ...29...