Connections to a Building Electrical System 

Connections  for  standby  power  to  a  building  electrical  system  must  be  made  by  a  qualified 
electrician. The connection must isolate the generator power from utility power and must comply 
with  all  applicable  laws  and  electrical  codes.  A  transfer  switch,  which  isolates  generator  power 
from utility power, is a prerequisite to a safe installation.  
 
 

 

 

 
 
Improper  connections  to  a  building  electrical  system  can  allow  electrical 
current from the generator to back feed into the utility lines. Such back feed 
may  electrocute  utility  company  workers  or  others  who  contact  the  lines 
during a power outage, and the generator may explode, burn or cause fires 
when  utility  power  is  restored.  Consult  the  utility  company  or  a  qualified 
electrician. 

 

Ground System  

The  portable  generators  have  a  system  ground  that  connects  generator  frame  components  to  the 
ground  terminals  in  the  AC  output  receptacles.  The  system  ground  is  not  connected  to  the  AC 
neutral wire. 
 

AC Applications  

Before connecting an appliance or power cord to the generator: 

!

 

Make sure that it is in good working order. Faulty appliances or power cords can create a 
potential for electrical shock.  

!

 

If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it 
off  immediately.  Disconnect  the  appliance  and  determine  whether  the  problem  is  the 
appliance or if the rated load capacity of the generator has been exceeded.  

!

 

Prior  to  powering  tools  and  equipment,  make  sure  the  generator’s  rated  voltage,  and 
amperage  capacity  (120VAC  @  27  AMPs)  is  adequate  to  supply  all  electrical  loads  that 
the unit will power. If powering exceeds the generator’s capacity, it may be necessary to 
group  one  or  more  of  the  tools  and/or  equipment  for  connection  to  a  separate  generator.  
Power levels between rated and maximum may be used for no more than 30 minutes.  

Summary of Contents for TPP-4500G-A

Page 1: ...ow all safety rules and instructions in this manual before attempting to operate this machine Failure to comply with these instructions may result in personal injury Diagrams within this manual may no...

Page 2: ...HE GENERATOR 18 STOPPING THE GENERATOR 19 OPERATION INSTRUCTIONS 20 MAINTENANCE 22 STORAGE 25 INSTALLATION 26 TROUBLESHOOTING 27 WIRING DIAGRAM 29 MODEL SPECIFICATIONS 29 The engine exhaust from this...

Page 3: ...s injury Read them carefully Please read the manual and pay attention to these sections Save These Important Safety Instructions Read and understand all of these safety instructions Be sure to retain...

Page 4: ...HEN USING AIR TOOLS BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY Specific Warnings Carbon Monoxide When this tool is running ensure that the area is well ve...

Page 5: ...MMABE MATERIALS NEAR THE GENERATOR Do not smoke or allow sparks flames or other sources of ignition around the engine and fuel tank Fuel vapors are explosive Keep grounded conductive objects such as t...

Page 6: ...void body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded Do not abuse the power cord for your too...

Page 7: ...ERATE THE GENERATOR WITH WET HANDS Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground Do not touch electrically energized parts of the generator...

Page 8: ...s Loose clothes jewelry or long hair can be caught in moving parts Avoid accidental starting Make sure the power switch is in its OFF position and disconnect the spark plug wire when not in use Remove...

Page 9: ...your model Accessories that may be suitable for one generator may become hazardous when used on another generator Servicing Maintain labels and nameplates on the generator and engine These carry impor...

Page 10: ...exhaust fumes must be within legal limits and installation must always meet local building codes If the generator is installed outdoors it must be weatherproofed and should be soundproofed It should n...

Page 11: ...loose clothing and jewelry away from moving parts Be aware that when engine parts are moving fast they cannot be seen clearly Keep access doors on enclosures closed and locked when access is not requ...

Page 12: ...ich could result in electrocution Do not connect to a building electrical system unless a qualified electrician has installed an isolation switch Fire and Burn Hazards The exhaust system gets hot enou...

Page 13: ...13 GENERATOR COMPONENTS See next page for further explanations...

Page 14: ...engine Return it gently to prevent damage to the starter When starting the engine by recoil starter set the key switch to the ON position and pull the recoil starter handle Fuel Valve The fuel valve...

Page 15: ...ne damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically stop the engine the engine...

Page 16: ...HP 800 1300 Kitchen Microwave Oven 1000 watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500...

Page 17: ...pstick and then screw the dipstick back into the oil fill hole FILL OIL ON A LEVEL SURFACE Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped o Remove the...

Page 18: ...d keep heat sparks and flame away from the gasoline and engine Refuel only outdoors Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified...

Page 19: ...e switch to return to the ON position Operating the starter motor for more than 5 seconds can damage the motor o Recoil start Pull the starter grip lightly until resistance is felt then pull briskly D...

Page 20: ...ave a system ground that connects generator frame components to the ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire AC Applications Before conne...

Page 21: ...lly shut down In this case wait a few minutes and then reset the circuitry system by turning the circuit breaker to its on position Restart the generator and continue powering the remaining tools and...

Page 22: ...nomical and trouble free operation It will also help reduce air pollution Improper maintenance or failure to correct a problem before operation can cause a malfunction in which you can be seriously in...

Page 23: ...djust Combustion Chamber Clean After every 500 hours Fuel tank and filter Clean Fuel Tube Check Every 2 years replace if necessary 1 Service more frequently when used in dusty areas 2 For commercial u...

Page 24: ...f the engine has not been running for a long time the sediment cup should be cleaned Turn the fuel valve to the OFF position Remove the sediment cup O ring and filter Clean the sediment cup O ring and...

Page 25: ...rrester Use a brush to remove carbon deposits from the spark arrester screen Inspect the screen for breaks or tears and replace it if necessary Install the spark arrester in the reverse order of remov...

Page 26: ...bute the oil evenly in the cylinder Reinstall the spark plug Change the engine oil After removal from storage drain the stored gasoline into a suitable container and fill the generator tank with fresh...

Page 27: ...o the concrete slab using 3 8 diameter expansion anchor bolts not supplied Connect a 6 AWG grounding wire not included from the ground connector 8 on the generator to a grounding rod not included that...

Page 28: ...fully close the choke Spark plug damaged Readjust gap and dry the spark plug Replace if necessary Carburetor dirty Clean the fuel sediment cup Replace or service the carburetor No electricity to the A...

Page 29: ...29...

Page 30: ...Dual Drop Dual Drop Dual Drop Dual Drop Dual Drop Electrical Automatic Voltage Regulation Yes Yes Yes Yes Yes Battery Maintenance Free Maintenance Free Maintenance Free Maintenance Free Maintenance F...

Reviews: