background image

 

 

Keep  your  work  area  clean  and  well  lit.    Cluttered  benches  and  dark  areas 
invite accidents. 
 
Do not operate power tools in explosive atmospheres, such as in the presence 
of  flammable  liquids,  gases,  or  dust.    Generators  create  sparks  which  may 
ignite the dust or fumes. 
 
Keep  bystanders,  children  and  visitors  away  while  operating  a  generator.  
Provide barriers or shields as needs. 

 

 

Personal Safety

 

 

 

Stay alert.

 Watch what you are doing, and use common sense when operating 

a generator. Do not use generator while tired or under the influence of drugs, 
alcohol,  or  medication.  A  moment  of  inattention  while  operating  generators 
may result in serious personal injury. 
 

Dress  properly.

  Do  not  wear  loose  clothing  or  jewelry.  Contain  long  hair. 

Keep your hair, clothing, and gloves away from moving parts. Loose clothes, 
jewelry, or long hair can be caught in moving parts. 
 

Avoid  accidental  starting.

  Make  sure  the  power  switch  is  in  its  “OFF” 

position and disconnect the spark plug wire when not in use. 
 

Remove  adjusting  keys  or  wrenches  before  turning  the  generator  on.

  A 

wrench  or  a  key  that  is  left  attached  to  a  rotating  part  of  the  generator  may 
result in personal injury. 
 

Do not overreach.

 Keep proper footing and balance at all times. 

 

Use  safety  equipment. 

Always  wear  eye  protection.  Wear  ANSI  approved 

safety  impact  eye  goggles.  Dust  mask,  non-skid  safety  shoes,  hardhat,  or 
hearing protection must be used for appropriate conditions. 
 

Do  not  force  the  generator.

  Use  the  correct  generator  for  your  application. 

The correct generator will do the job better and safer at the rate for which it is 
designed. 
 

Do  not  use  the  generator  if  the  power  switch  does  not  turn  it  off.

  Any 

generator  that  cannot  be  controlled  with  the  power  switch  is  dangerous  and 
must be replaced.

 

 

 

Generator Use and Care

 

Summary of Contents for TPP-4500G-A

Page 1: ...ow all safety rules and instructions in this manual before attempting to operate this machine Failure to comply with these instructions may result in personal injury Diagrams within this manual may no...

Page 2: ...HE GENERATOR 18 STOPPING THE GENERATOR 19 OPERATION INSTRUCTIONS 20 MAINTENANCE 22 STORAGE 25 INSTALLATION 26 TROUBLESHOOTING 27 WIRING DIAGRAM 29 MODEL SPECIFICATIONS 29 The engine exhaust from this...

Page 3: ...s injury Read them carefully Please read the manual and pay attention to these sections Save These Important Safety Instructions Read and understand all of these safety instructions Be sure to retain...

Page 4: ...HEN USING AIR TOOLS BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY Specific Warnings Carbon Monoxide When this tool is running ensure that the area is well ve...

Page 5: ...MMABE MATERIALS NEAR THE GENERATOR Do not smoke or allow sparks flames or other sources of ignition around the engine and fuel tank Fuel vapors are explosive Keep grounded conductive objects such as t...

Page 6: ...void body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded Do not abuse the power cord for your too...

Page 7: ...ERATE THE GENERATOR WITH WET HANDS Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground Do not touch electrically energized parts of the generator...

Page 8: ...s Loose clothes jewelry or long hair can be caught in moving parts Avoid accidental starting Make sure the power switch is in its OFF position and disconnect the spark plug wire when not in use Remove...

Page 9: ...your model Accessories that may be suitable for one generator may become hazardous when used on another generator Servicing Maintain labels and nameplates on the generator and engine These carry impor...

Page 10: ...exhaust fumes must be within legal limits and installation must always meet local building codes If the generator is installed outdoors it must be weatherproofed and should be soundproofed It should n...

Page 11: ...loose clothing and jewelry away from moving parts Be aware that when engine parts are moving fast they cannot be seen clearly Keep access doors on enclosures closed and locked when access is not requ...

Page 12: ...ich could result in electrocution Do not connect to a building electrical system unless a qualified electrician has installed an isolation switch Fire and Burn Hazards The exhaust system gets hot enou...

Page 13: ...13 GENERATOR COMPONENTS See next page for further explanations...

Page 14: ...engine Return it gently to prevent damage to the starter When starting the engine by recoil starter set the key switch to the ON position and pull the recoil starter handle Fuel Valve The fuel valve...

Page 15: ...ne damage caused by an insufficient amount of oil in the crankcase Before the oil level in the crankcase can fall below a safe limit the Oil Alert system will automatically stop the engine the engine...

Page 16: ...HP 800 1300 Kitchen Microwave Oven 1000 watt 1000 Coffee Maker 1500 Electric Stove Single Element 1500 Hot Plate 2500 Family Room DVD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 500...

Page 17: ...pstick and then screw the dipstick back into the oil fill hole FILL OIL ON A LEVEL SURFACE Check the oil level BEFORE EACH USE with the generator on a level surface and the engine stopped o Remove the...

Page 18: ...d keep heat sparks and flame away from the gasoline and engine Refuel only outdoors Wipe up spills immediately Use unleaded gasoline with a pump octane rating of 86 or higher This engine is certified...

Page 19: ...e switch to return to the ON position Operating the starter motor for more than 5 seconds can damage the motor o Recoil start Pull the starter grip lightly until resistance is felt then pull briskly D...

Page 20: ...ave a system ground that connects generator frame components to the ground terminals in the AC output receptacles The system ground is not connected to the AC neutral wire AC Applications Before conne...

Page 21: ...lly shut down In this case wait a few minutes and then reset the circuitry system by turning the circuit breaker to its on position Restart the generator and continue powering the remaining tools and...

Page 22: ...nomical and trouble free operation It will also help reduce air pollution Improper maintenance or failure to correct a problem before operation can cause a malfunction in which you can be seriously in...

Page 23: ...djust Combustion Chamber Clean After every 500 hours Fuel tank and filter Clean Fuel Tube Check Every 2 years replace if necessary 1 Service more frequently when used in dusty areas 2 For commercial u...

Page 24: ...f the engine has not been running for a long time the sediment cup should be cleaned Turn the fuel valve to the OFF position Remove the sediment cup O ring and filter Clean the sediment cup O ring and...

Page 25: ...rrester Use a brush to remove carbon deposits from the spark arrester screen Inspect the screen for breaks or tears and replace it if necessary Install the spark arrester in the reverse order of remov...

Page 26: ...bute the oil evenly in the cylinder Reinstall the spark plug Change the engine oil After removal from storage drain the stored gasoline into a suitable container and fill the generator tank with fresh...

Page 27: ...o the concrete slab using 3 8 diameter expansion anchor bolts not supplied Connect a 6 AWG grounding wire not included from the ground connector 8 on the generator to a grounding rod not included that...

Page 28: ...fully close the choke Spark plug damaged Readjust gap and dry the spark plug Replace if necessary Carburetor dirty Clean the fuel sediment cup Replace or service the carburetor No electricity to the A...

Page 29: ...29...

Page 30: ...Dual Drop Dual Drop Dual Drop Dual Drop Dual Drop Electrical Automatic Voltage Regulation Yes Yes Yes Yes Yes Battery Maintenance Free Maintenance Free Maintenance Free Maintenance Free Maintenance F...