6. To drain water from the internal tank properly, you need to use the drain
hole (only for FSM6/FSM4 line) (it is necessary to unscrew a plug, covering
the drain hole), water can also be drained through a composite relief valve
(Fig. 11) (unscrew the composite relief valve drain knob screw and set the
drain knob to the upper position, at that hot water tap must be open, and
cold water supply valve must be closed).
7. Bear in mind to check serviceability of the relief valve every 14 days –
inspection method:
- turn the discharge lever to the left up until you feel the change of thread,
then water must start flowing from the valve’s hole. After checking the
water flow, return the lever to its initial position.
8. If necessary, wipe external surfaces of the heater by a damp cloth with
soap.
Possible malfunctions and troubleshooting methods
Table 4
ERROR CODES
For models FSM5/FSM6
Table 5
10. TROUBLESHOOTING AND ERROR CODES
Failure
Possible causes
Troubleshooting method
Heating indicator light doesn’t light up,
water is not heated
1. Temperature adjustment device
is broken.
Contact a repairer, TIMBERK service
center.
2. Temperature limiter was actuated or
was not switched on.
Switch on the temperature switch
following instructions on its activation.
(page 15)
3. Temperature limiter is broken.
Contact a repairer, TIMBERK service
center.
Water doesn’t flow from the hot water
discharge cock
1. Water feed is cut off.
1. Wait until water supply is restored.
2. Water pressure is too low.
2. Switch on the water heater again,
when normal water pressure restores.
3. Water supply exhaust valve is
closed.
Water temperature is too high
Water temperature control system
is damaged.
Contact a repairer, TIMBERK service
center.
Water leakage
Seal at the point of pipe connection
is broken.
Replace the joint seal.
Water flows from the appliance’s case
Breaking of the internal tank
(corrosion)Seal at the point of the
heating element connection is broken.
Contact a repairer, TIMBERK service
center.
Failure
Cause
Troubleshooting method
E1
Dry heating
Check if there is water in the water
heater
E2
Temperature sensor malfunction
Contact the authorized service center.
E3
Current leakage
Contact the authorized service center.
E4
Water overheating
Contact the authorized service center.
11. TRANSPORTATION AND STORAGE
CONDITIONS
Temperature
requirements*
Humidity
requirements*
Transportation and
storage
From -30° to +50°
From 15% to 85%
(without a condensate)
We are exploring new technologies and we constantly improving the quality
of our products. That’s why specifications, design and accessories are
subject to change without any specific notice.
temperature
limlter
hating power switch
indication
light
termostat
indication light
power board
heating element
12. WIRING DIAGRAM
Серия FSM3/FSМ4
Fig. 16
Серия FSM5/ FSM6
Fig. 17
The water heater should be disposed upon the end of life. You can obtain
detailed information on water heater disposal from a representative of local
authorities.
Device service life is 10 years.
13. DISPOSAL
14. SERIAL NUMBER AND PRODUCTION DATE
Serial number, production month and year are included in ID LINE product
code. Sticker with ID LINE code is pasted on product surface. Month and
two last numbers of year is putted after symbol “-“.
NOTE:
Technical and any other characteristics of the
appliance can be revised.
Such changes may be introduced without warning and
prior notice to the consumers.
The manufacturer shall not be liable for changes in the
appliance’s wiring diagram that may be implemented
without notice to the consumers.
Summary of Contents for SWH FSM3 100 V
Page 21: ...www timberk com ...