background image

www.timberk.com • electrical storage water heater

www.timberk.com • electrical storage water heater

17

16

6. To drain water from the internal tank properly, you need to use the drain 

hole (only for FSM6/FSM4 line) (it is necessary to unscrew a plug, covering 

the drain hole), water can also be drained through a composite relief valve 

(Fig. 11) (unscrew the composite relief valve drain knob screw and set the 

drain knob to the upper position, at that hot water tap must be open, and 

cold water supply valve must be closed).
7. Bear in mind to check serviceability of the relief valve every 14 days – 

inspection method:
- turn the discharge lever to the left up until you feel the change of thread, 

then water must start flowing from the valve’s hole. After checking the 

water flow, return the lever to its initial position.
8. If necessary, wipe external surfaces of the heater by a damp cloth with 

soap.

Possible malfunctions and troubleshooting methods
Table 4

ERROR CODES

For models FSM5/FSM6
Table 5

10. TROUBLESHOOTING AND ERROR CODES

Failure

Possible causes

Troubleshooting method

Heating indicator light doesn’t light up, 
water is not heated

1. Temperature adjustment device 
is broken.

Contact a repairer, TIMBERK service 
center.

2. Temperature limiter was actuated or 
was not switched on.

Switch on the temperature switch 
following instructions on its activation. 
(page 15)

3. Temperature limiter is broken.

Contact a repairer, TIMBERK service 
center.

Water doesn’t flow from the hot water 
discharge cock

1. Water feed is cut off.

1. Wait until water supply is restored.

2. Water pressure is too low.

2. Switch on the water heater again, 
when normal water pressure restores.

3. Water supply exhaust valve is 
closed.

Water temperature is too high

Water temperature control system 
is damaged.

Contact a repairer, TIMBERK service 
center.

Water leakage

Seal at the point of pipe connection 
is broken.

Replace the joint seal.

Water flows from the appliance’s case

Breaking of the internal tank 
(corrosion)Seal at the point of the 
heating element connection is broken.

Contact a repairer, TIMBERK service 
center.

Failure

Cause

Troubleshooting method

E1

Dry heating

Check if there is water in the water 
heater

E2

Temperature sensor malfunction

Contact the authorized service center.

E3

Current leakage

Contact the authorized service center.

E4

Water overheating

Contact the authorized service center.

11. TRANSPORTATION AND STORAGE 

CONDITIONS

Temperature 

requirements*
Humidity 

requirements*

Transportation and 

storage

From -30° to +50°

From 15% to 85% 

(without a condensate)

We are exploring new technologies and we constantly improving the quality 

of our products. That’s why specifications, design and accessories are 

subject to change without any specific notice.

temperature

limlter

hating power switch

indication

light

termostat

indication light 

power board

heating element

12. WIRING DIAGRAM

Серия FSM3/FSМ4

Fig. 16

Серия FSM5/ FSM6

Fig. 17

The water heater should be disposed upon the end of life. You can obtain 

detailed information on water heater disposal from a representative of local 

authorities.
Device service life is 10 years.

13. DISPOSAL

14. SERIAL NUMBER AND PRODUCTION DATE

Serial number, production month and year are included in ID LINE product 

code. Sticker with ID LINE code is pasted on product surface. Month and 

two last numbers of year is putted after symbol “-“.

NOTE:

Technical and any other characteristics of the 

appliance can be revised.
Such changes may be introduced without warning and 

prior notice to the consumers.
The manufacturer shall not be liable for changes in the 

appliance’s wiring diagram that may be implemented 

without notice to the consumers.

Summary of Contents for SWH FSM3 100 V

Page 1: ... H SWH FSM6 80 H SWH FSM6 100 H SWH FSM3 30 V SWH FSM3 50 V SWH FSM3 80 V SWH FSM3 100 V SWH FSM4 30 H SWH FSM4 50 H SWH FSM4 80 H SWH FSM4 100 H Electrical storage water heater Outlook of devices aslo colour scores can be revised without any special advance notices Производитель вправе менять внешний вид прибора и цветовую гамму при бора без специального уведомления FSM5 FSM6 FSM3 FSM4 ...

Page 2: ...ons may harm health of the user and other people as well as damage their property 1 Any electrical appliance must be supervised when in operation espe cially if there are children nearby Make sure children do not touch the ap pliance 2 Prior to installing the water heater not connecting it to electrical main check and make sure the outlet for the water heater has a ground pin and if it is properly...

Page 3: ...7 8 7 8 7 8 7 Rated power W 2000 2000 2000 2000 Stage power W 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Tank capacity L 30 50 80 100 Rated pressure Mpa 0 7 0 7 0 7 0 7 Water protection class IPX4 IPX4 IPX4 IPX4 Heating time at Δ 30 ºC min 28 46 73 80 Appliance dimensions mm 550x435x238 855x435x238 991x493x270 1190x493x270 Weight kg 9 8 13 4 18 9 23 4 Factual year energy consumption k...

Page 4: ... 5 heating element 6 right composite protective cover 7 temperature sensor case 8 composite pressure safety valve be sure to install onto the cold water supply tube Pos A 9 emergency discharge of surplus water pressure a small water leakage is possible from the emergency discharge hole when the water heater is operating It is normal 10 inlet nozzle with a splitter 11 hot water outlet nozzle 12 eme...

Page 5: ...umber of consumption points to the outlet nozzle marked red 7 Check leak integrity of joints open the shut off cock and one of the cock assemblies After the tank is filled with water as evidenced by issue of water from the cock assembly shut the cock assembly and check the leak integrity of all joints Connection to water main 1 The heater must be connected to water main with at least 0 1 MPa press...

Page 6: ... connected to the outlet Do it in the following order insert the power plug into the outlet switch off the water heater after half hour operation and unplug the cord check if the plug is heated by your hand If the plug is heated over 50 C then to prevent damages accidents and fire as a result of bad electrical contact replace the outlet with a new one A specialist must do this 3 Power cord of the ...

Page 7: ... used to activate timer and night heating 8 button It is used to increase the selected value 9 MODE button It is used to set time and timer 1 Time indication 2 Timer activation indicator It lights up when water heater on off timer is activated 3 Energy save indicators They light up when selecting low heating power 800 W 4 Water heater water temperature indicator 5 Mode button It is used to set tim...

Page 8: ...night heating at that indicator on the display will light up 6 2 Press timer button twice again to deactivate night heating at that indicator on the display will light down 7 Timer and night heating Timer and night heating can be activated simultaneously For this purpose it is necessary to press timer button several times until timer and night heating indicators light up simultaneously 8 Control p...

Page 9: ...h Water temperature control system is damaged Contact a repairer TIMBERK service center Water leakage Seal at the point of pipe connection is broken Replace the joint seal Water flows from the appliance s case Breaking of the internal tank corrosion Seal at the point of the heating element connection is broken Contact a repairer TIMBERK service center Failure Cause Troubleshooting method E1 Dry he...

Page 10: ...нтура в вашей электросети эксплуатация водонагревателя опас на для жизни 3 Подключайте водонагреватель только к сети 230В 50Гц При не обходимости выясните характеристики своей сети у поставщиков электроэнергии 4 Во избежание перегрева и риска возникновения пожара а также повреждения внутренней электрической сети не изменяйте длину сетевого шнура и не подключайте водонагреватель через электри чески...

Page 11: ...0 230 50 Номинальная сила тока A 8 7 8 7 8 7 8 7 Номинальная потребляемая мощность Вт 2000 2000 2000 2000 Мощность по ступеням Вт 800 1200 2000 800 1200 2000 800 1200 2000 800 1200 2000 Объем л 30 50 80 100 Номинальное давление МПа 0 7 0 7 0 7 0 7 Класс влаго защиты IPX4 IPX4 IPX4 IPX4 Класс защиты I I I I Время нарева при Δ 30 ºC мин 28 46 73 80 Размеры прибора мм 550x435x238 855x435x238 991x493x...

Page 12: ...лектрический водонагреватель следует устанавливать на прочной стене 2 Стена на которой устанавливается электрический водонагрева тель должна выдерживать как минимум двойной вес водонагрева теля полностью заполненного водой на стене должны отсутствовать трещины и другие повреждения В противном случае необходимо при нять меры для усиления крепления или установить водонагреватель на специальной опоре...

Page 13: ...керные болты следует преду смотреть свободное пространство между нижней частью водонагревателя и полом не менее 0 6 м а для серии FSM6 FSM4 ещё и свободное про странство между боковой крышкой с правой стороны и стеной для обеспечения удобства тех нического обслуживания при необходимости его проведения Монтаж водонагревателя 1 Электрический водонагреватель следует устанавливать на проч ной стене Ес...

Page 14: ...роверку проводите в следующем порядке вставьте электрическую вилку в розетку через полчаса работы выключите водонагреватель и вынь ВНИМАНИЕ Перед подключением накопительного водона гревателя убедитесь в том что водонагреватель заземлен надлежащим образом Правильное за земление важно для минимизации ударов током и опасности возгорания Шнур питания оснащён вилкой с контактом заземления Устройство до...

Page 15: ...ньшаете температуру нагрева воды 3 4 Водонагреватель автоматически поддерживает температуры воды Когда температура воды внутри водонагревателя достигает установленной пользователем температуры нагрев автоматически выключается при этом на панели управления светится только инди катор питания голубого цвета Когда температура воды внутри водонагревателя понижается ниже установленного уровня нагрев авт...

Page 16: ...лятора против часовой стрелки от по зиции max к позиции min или нажмите кнопку чтобы умень 3 Выбор режима мощности 3 1 Нажмите на ручку терморегулятора на панели управления несколь ко раз или на соответствующие кнопки на ПДУ чтобы выбрать необхо димую мощность нагрева 3 2 При выборе низкой мощности нагрева на панели управления за гораются индикаторы energy save а на дисплее отображается инди катор...

Page 17: ...тся рядом с ТЭНом имеет круглую форму рис 14 для вертикальных водонагревателей серии FSM5 FSM3 нажать до щелчка кнопку расположенную по центру термовыключателя рис 15 если кнопка не нажимается и нет щелчка то подождать пока термо 6 Чтобы правильно слить воду из внутреннего бака надо восполь зоваться сливным отверстием только для серии FSM6 FSM4 надо открутить заглушку закрывающую сливное отверстие...

Page 18: ...ие электросхемы изделия которое может быть выполнено без уведомления потребителя По окончании срока службы водонагреватель следует утилизировать Подробную информацию по утилизации водонагревателя Вы можете получить у представителя местного органа власти Срок службы во донагревателя составляет 15 лет 13 УТИЛИЗАЦИЯ Серийный номер изделия месяц и год изготовления указаны в со ставе ID LINE кода издел...

Page 19: ...ей техники Timberk мы дополнительно сообщаем что русский является государствен ным языком в следующих госу дарствах в Российской Федерации в Республике Беларусь наряду с белорусским языком в частично признанной Южной Осетии наряду с осетинским языком Русский язык является офици альным языком во всех случаях другой язык или другие языки выступают как государствен ный или второй официальный в следую...

Page 20: ...рический накопительный водонагреватель 39 38 Если вы заметили ошибку в руководстве пожалуйста сообщите нам об этом связавшись с нами по электронной почте указанной на сайте www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com ...

Page 21: ...www timberk com ...

Reviews: