www.timberk.com • electrical storage water heater
10
11. TROUBLESHOOTING
All the disorders in operation of the water heater should be fixed as well
as putting of the appliance in long-term storage should be performed in
appropriate service centres. The water heater must be prepared for long-term
inactivity only by specially trained qualified specialists, because improperly
performed repair can result in hazard during water heater operating.
You can ask the seller for the address of the nearest service centre or find it
on the website www.timberk.com.
Table 3
Possible malfunctions and troubleshooting methods
IMPORTANT!
If these actions have no positive result or the
temperature limiter turns off repeatedly during a short
period of time then you should unplug the water
heater from the electrical main, cut off water supply
and contact your local Timberk Authorized Service
Centre for a consultation or repair of the appliance.
IMPORTANT!
If water does not flow then the valve is damaged.
In this case you must not use the heater; it is
recommended to call for a service technician.
6. Bear in mind to check serviceability of the pressure safety valve every 14
days. The inspection method is as follows:
- turn the handle for draining to the upper position until you feel the change
of thread, then water must start flowing out from the valve opening; after
checking the water outflow return the handle to its initial position.
7. Wipe external surfaces of the water heater by a damp cloth with soap
when necessary.
Failure
Possible causes
Troubleshooting method
Heating indicator light doesn’t light up,
water is not heated
1. Temperature adjustment device
is broken.
Contact a repairer, TIMBERK service
center.
2. Temperature limiter was actuated or
was not switched on.
Switch on the temperature switch
following instructions on its activation.
(page 15)
3. Temperature limiter is broken.
Contact a repairer, TIMBERK service
center.
Water doesn’t flow from the hot water
discharge cock
1. Water feed is cut off.
1. Wait until water supply is restored.
2. Water pressure is too low.
2. Switch on the water heater again,
when normal water pressure restores.
3. Water supply exhaust valve is
closed.
Water temperature is too high
Water temperature control system
is damaged.
Contact a repairer, TIMBERK service
center.
Water leakage
Seal at the point of pipe connection
is broken.
Replace the joint seal.
Water flows from the appliance’s case
Breaking of the internal tank
(corrosion)Seal at the point of the
heating element connection is broken.
Contact a repairer, TIMBERK service
center.
Heating indicator light lights up but
water is not heated
1. Temperature adjustment device
is broken.
1. Contact a repairer, TIMBERK
service center.
2. Insufficient time for heating.
2. Wait until water is heated.
3. Heating element is broken.
3. Contact a repairer, TIMBERK
service center.
Summary of Contents for SWH SE1 10 VO