www.timberk.com • electrical storage water heater
8
IMPORTANT!
To guarantee reliable operation and safe use of the
water heater check prior to the first run if it is properly
connected to the 220V AC electrical main. The water
heater to be connected must be securely wired up to
the earth loop of your electrical main.
IMPORTANT!
Power outlet must be designed for rated current of
10A at least; copper-conductor power cord must be
at least 3x1.5 mm2 in cross-section (for copper).
IMPORTANT!
Water can drip from the pressure safety valve upon
heating. IT IS IMPOSSIBLE TO AVOID DRIPPING
AND IT IS FORBIDDEN TO PREVENT IT BECAUSE
IT CAN RESULT IN TANK RUPTURE (IN THE CASE
OF EQUIPMENT FAILURE). Working ability of the
pressure safety valve should be inspected every
14 days. The inspection method is described in the
section 9 (MAINTENANCE).
8. HOW TO CONTROL WATER HEATER
OPERATIONS
Control panel (fig. 8)
Control panel (fig. 8)
Fig. 8
1. Thermostate handle
2. «HEATING» indicator lamp
9. WATER HEATER CONTROL
10. MAINTENANCE
1. At first, open one of the outlet valves on the outlet of the water heater;
then open the inlet valve. The electric water heater will start filling in with
water. When water flows from the outlet valve freely it means that the water
heater is fully filled with water, and you can close the outlet valve.
Warning: During normal operation the inlet valve must be set open.
2. Plug the power cord into the outlet, after this the handle light will be on.
1. Check the power plug and outlet as often as possible. Secure electrical
contact and proper grounding must be granted. The plug and outlet must
not heat excessively.
2. If the water heater is not used for a long time, especially in regions with
3. Set the desired temperature of water by the temperature controller
handle by rotating the handle; “HEATING” indicator lamp (fig. 8) will flash
on. When water reaches the preset temperature “HEATING” indicator lamp
will go out. When water temperature drops to a certain level heating will
be switched on automatically and restore the required water temperature.
4. After rotating the handle to the position «MIN» the minimum temperature
+30°C (± 5°C) would be seted. After puting the handle in to position «MAX»,
the maximum temperature would be set +70°C (± 5°C).
5. There is a “COMFORT” sign on the panel. It signifies optimal temperature
of heating. Fixing the temperature controller handle in position “COMFORT”
you choose the most efficient mode of electricity consumption.
6. To turn off the water heater set the switch handle to position « » and
unplug the power cord.
Summary of Contents for SWH SE1 10 VO