Poor atomizing
(insufficient
performance)
Remedy
Defect
Possible cause
The unit is operating in
a light mode (low
atomizing frequency)
No defect. If necessary to switch to the intensive
mode, press Atomizing frequency button in
the manual setting mode and switch the unit
to the intensive operation mode.
Atomizer is clogged
Clean the atomizer
Tank water temperature
is too low
Set the maximum performance. Humidifier s
performance will be increased in 10 minutes
No atomizing
The plug is poorly
inserted into an outlet
Connect the plug into an outlet carefully
Red light on the water
indicator has illuminated
and went out (water
tank is completely empty)
Add water to the tank
A white residue appeared
on objects around the
humidifier (salts,
separating from water)
Lime deposits are formed
on the membrane
Clean the humidifiers membrane by a special brush
Water demineralization
cartridge is worn down
(ion exchange resin)
Replace the cartridge
No warm atomizing
Use of warm steam is
not selected
Press warm steam button in the manual setting
mode and switch the unit to a warm steam
humidification mode
Operation has just started No defect. It will take about 10-20 minutes
for warm steam to be atomized (time, required
for water heating by the heater after
it s switched on)
Difference between the
level of current humidity
and readings of a
humidity recorder
is too big
Dirt accumulation
inside an air vent
Clean the air vent.
Even in one room humidity
can be different depending on the location
The unit is operated in
places, where it is affected
by the environment,
for example, by a window
Install the unit in places, where it cannot be
affected by the environment
Steam has an
unpleasant odor
Signal 1 is given
Signal 2 is given
Not fresh water in use
Tank full sound signal
Fan operation
sound signal
There are remains of
not fresh water or litter
in the water groove
Clean the unit in accordance with the cleaning
and maintenance manual and fill it with fresh
water
No defect in the unit, keep on its operation
Table
5
11. Utilization
If you are unable to solve issues by means of mentioned methods, contact
a service center.Life of the humidifier is
2
years.
Upon expiration of the humidifier it must be disposed in accordance with
regulations, rules and by means, currently in force at a disposal station.
www.timberk.com
electric humidifier
Summary of Contents for THU UL 05
Page 12: ...12 www timberk com 3 6 4 7 5 6 8 7 7 1 POWER AUTO 1 2 3 40 4 5 6 10 25 10 20...
Page 14: ...14 www timberk com 7 6 40 7 7 1 8 1 7 8 8 9 400 180 6 L M H 60 30 20 11 40 80 5...
Page 15: ...15 www timberk com 9 9 1 9 2 10 9 3 11 9 4 9 5 10 5...