background image

www.timberk.com • электрический увлажнитель воздуха

6

Prior to cleaning the unit make sure the power supply’s plug is disconnected 

from the outlet. Otherwise, it may cause electric shock.
Prior to cleaning wait until water, remaining in the unit’s case, completely 

8. CLEANING AND MAINTENANCE

IMPORTANT! 

To avoid electric shock, prior to disassembling the 

unit (removing the tank), disconnect the unit from the 

power line! Do not fill the tank with other liquids but 

tap water.
Different composition of liquids has harmful effect on 

internal parts and causes failures.
Do not fill the unit or the water tank with such 

additives as essential oils, fragrances, cleaning 

agents, chemical medical drugs, warm water (above 

40°), etc.
Otherwise, the water tank and internal parts of the 

unit will be damaged and inoperable.
Do not fill water directly into the internal part of the 

unit or the atomizer.
Water inside the unit may cause failure of the unit.
Do not hit or throw the water tank. It may get damaged 

resulting in water leaks. Do not use the unit in case if 

the water tank is heavily hit.
Immediately contact the technical support service or 

the maintenance and repair station.
Every day fill the tank with fresh water and keep the 

unit clean.

7. OPERATION OF THE UNIT

Install the unit to a true vertical on an even and dry surface, then connect 

it to the power line, having filled the tank with water first, at the same time 

the «      » indicator will be blinking on the LCD display.
Press the «      » button and the unit will automatically start operating, and 

indicators will show up on the LCD display.
At the very beginning of operation, the atomizing level may appear 

unstable, which is caused by the temperature difference and water quality. 

It takes some time for water to start turning into steam on the ultrasonic 

membrane. After 10-25 minutes the atomizing level will gradually stabilize.
To select the operation mode and change the steam outflow intensity press 

the «      » button several times, the steam outflow intensity will be changed 

each time and shown on the display by indicators.
The display shows the current humidity level and temperature.
The unit will be turned off if water is completely used up, at the same time 

the no water indicator «      » will light up.
To continue operation of the unit, add water in accordance with the 

instructions (section 6 Filling the tank with water).
In the automatic operation mode (A indicator) the steam outflow intensity 

will be adjusted automatically.
If the relative humidity level is less than 40% then the humidifier will operate 

in the 6th steam outflow intensity mode.
If the relative humidity level is 40% to 50% then the humidifier will operate 

in the 4th steam outflow intensity mode.
If the relative humidity level is 50% to 60% then the humidifier will operate 

in the 3rd steam outflow intensity mode.
If the relative humidity level is over 60% then the humidifier will operate in 

the 1st steam outflow intensity mode.
The unit is equipped with a compartment for aromatic oil. If aromatic oil is 

added to this compartment then there will be air aromatization. Aromatic 

oil is not included in the scope of delivery. To remove the compartment for 

aromatic oil press button 7 (see Fig. 1).
To turn off the unit press the «      » button.

NOTE:

When using the humidifier, you may come across 

condensate generation on its upper part and objects 

next to it, including water accumulation, which is not 

a defect, but a feature of its operation. This feature 

may have several causes, listed in table 2 on page 7.

Summary of Contents for THU UL 08

Page 1: ...umidifier THU UL 08 W white BL black O orange Specified in the additional marks of modes name The colors for the whole unit and or its parts Outlook of devices aslo colour scores can be revised withou...

Page 2: ...a tag specifying all necessary technical data and other useful information about the unit Use this unit only for the purpose listed in this manual The humidifier is intended to humidify room air Comf...

Page 3: ...s of the ultrasonic humidifier membrane are not audible and are completely safe for people and pets service center Take the power cord out from an electric outlet in the following cases prior to water...

Page 4: ...ifferent types of the product Fig 1 Fig 2 3 SPECIFICATION 4 APPLIANCE DESCRIPTION Table 1 Technical specifications Unit of measurement Value Humidification capacity ml h 220 Supply voltage V Hz 220 50...

Page 5: ...number All indicators correspond to some or other operation mode depending on user presets 1 Turn the water tank lock lever to position holding the unit vertically Fig 4 1 2 Unscrew the tank s cover c...

Page 6: ...by the temperature difference and water quality It takes some time for water to start turning into steam on the ultrasonic membrane After 10 25 minutes the atomizing level will gradually stabilize To...

Page 7: ...d without any prior notice Products must be stored in dry ventilated storages at the temperature not lower than 30 C Transportation and storage 30 to 50 15 to 85 no condensate cools down to avoid gett...

Page 8: ...t odor Stale water is used Clean the unit according to the cleaning and servicing instructions and fill the tank with fresh water Remains of stale water or waste have accumulated in the unit s case or...

Page 9: ...www timberk com 9 1 2 3 4 5 6 7 8 9 10 11 12 9 10 11 11 12 12 13 14 14 15 15 16 imberk 40 60 1...

Page 10: ...www timberk com 10 2...

Page 11: ...www timberk com 11 3 4 1 2 3 4 5 LCD 6 7 8 9 5 20 1 1 220 220 50 1 4 25 0 16 0 18 IPX2 ll 255x193x312 300x240x325 1 41 2 15 2 30 35 2...

Page 12: ...www timberk com 12 1 2 8 3 4 5 6 7 5 1 1 2 1 3 1 4 1 5 1 1 2 3 4 5 6 7 8 1 4 1 2 4 2 3 4 3 4 5 3 6 4 1 4 3 4 2 10 11 12 13 14 15 16 17...

Page 13: ...www timberk com 13 LCD 10 25 6 40 6 40 50 4 50 60 3 60 1 7 1 7 40 LCD...

Page 14: ...www timberk com 14 8 9 1 2 3 30 50 15 85 3 15...

Page 15: ...www timberk com 15 2 2 3 10 30 2 11...

Page 16: ...3 115162 28 4 7 495 6044266 7 495 6044266 P 52161 2 30 2007 P 51318 14 1 2006 4 P 51318 14 2 2006 p 5 7 P 51317 3 3 2008 P 51317 3 2 2006 p 6 7 RU C IL AB71 B 00081 05 07 2012 04 07 2015 10 88000 972...

Page 17: ...www timberk com 17 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru www btpart ru...

Page 18: ...www timberk com 18 Timberk c 10...

Page 19: ...www timberk com 19 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Page 20: ...www timberk com...

Reviews: