Table 2
Problem
Possible cause
Remedy
Poor atomizing (insufficient
capacity)
The unit is operating in
the minimized mode (low
atomizing frequency)
There is no problem. If
you need to switch to
the intensive mode of
operation, turn the regulator
handle all the way to
the right.
The atomizer is clogged
Clean the atomizer.
Temperature of water in the
tank is too low
Set maximum capacity. The
humidifier’s capacity will go
up after a while.
No atomizing
The power cord is poorly
connected to the outlet
Connect the power cord into
the outlet carefully
There is white deposit
on objects around
the humidifier (salts,
separating out from water)
1. Lime deposits have
formed on the membrane
2. There is a lot of salts in
the water used (calcium and
magnesium)
1. Clean the humidifier’s
membrane with a special
brush
2. Use filtered water
Steam has an unpleasant
odor
Stale water is used
Clean the unit according to
the cleaning and servicing
instructions and fill the tank
with fresh water
Remains of stale water or
waste have accumulated
in the unit’s case or the
atomizer
Condensate is formed on the
upper part of the humidifier
and on surrounding objects,
when it is operating.
1. High humidification
intensity is set.
2. High room humidity and
temperature.
Lower the humidification
intensity by turning the
on/off and steam outflow
intensity regulator
counterclockwise.
Water appears next to
the humidifier, when it is
operating.
1. High humidification
intensity is set.
2. Lime deposits have
formed on the membrane
and in grooves for water (in
the unit’s base).
1. Lower the humidification
intensity by turning the
on/off and steam outflow
intensity regulator
counterclockwise.
2. Clean the unit according
to the cleaning and
servicing instructions.
Water appears next to the
humidifier, when it is not
operating
Water tank is leaking
You need to contact an
authorized service center
Temperature
requirements*
Humidity
requirements*
Transportation
and storage
-30 °C to +50 °C
15 % to 85 %
(no condensate)
We are researching new technologies and constantly improving
the quality of our products. Specifications, design and scope
of delivery may be changed without any prior notice.
1. When transporting, any possible impacts and movements
of the package inside a vehicle must be avoided.
2. Handling symbols on the unit’s package must be strictly
observed when transporting and storing it.
3.
11. TRANSPORTATION AND STORAGE
* Products must be stored in dry, ventilated storages at the
temperature not lower than -30°C.
Service life of the humidifier is 2 years.
At the end of its service life the humidifier should be utilized
in accordance with regulations and procedures, which are
in force at the place of utilization.
12. UTILIZATION