FLOOR PROTECTION REQUIREMENTS INSTALLATION
29.4A
Installation into a manufactured home or mobile home should be installed in
accordance with the Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard,
CAN/CSA Z240 MH Series, in Canada.
The appliance must be grounded to the steel chassis of the mobile home
(Some states do not require this; check with your local building department).
!
WARNING
DO NOT INSTALL IN A SLEEPING ROOM.
THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING ROOF
MUST BE MAINTAINED.
3.6 OUTSIDE
AIR
Available from your Authorized Dealer (114KT)
Outside air must not be drawn from an enclosed space (garage, unventilated crawl space).
NOTE: Wolf Steel Ltd. strongly suggests using outside air for all residential installations, especially for
those that are energy effi cient, air-tight homes.
Outside air supply must not be over 15' (4.6m) long.
Outside air vents must be made with 1 3/4" (45mm) diameter or larger metal or aluminum duct with a metal
screen attached to the end to keep out rodents (P.V.C. or other materials may not be used).
The outside air inlet must not be above or within 12" (305mm) of the chimney termination, must have a rain
cap or down-turned elbow to prevent the water from entering and be located so that it will not become
plugged by snow or other material.
Outside air is required for all combustible built-in enclosure installations.
STOVE
ILLUSTRATED
The appliance must be installed on a non-combustible fl oor protector extending the full depth of the
appliance and extending a minimum 6" (152mm) in front and on either side (minimum .018" thick - 26 gauge)
of the fuel loading and ash removal openings.
The fl oor protector must extend under and 2" (51mm) beyond each side and back of a "Tee" (if used).
NOTE: Floor protection is required for spark and ash shielding, but not for limiting fl oor temperatures
from the radiant heat of the appliance. The appliance was designed and safety tested so that without
any protection, the fl oor would not overheat.
Refer to local building codes for suitable fl oor protection materials.
3.7 MOBILE
HOME