background image

CONNECTION

Connect the cable to the terminal block on the unit as follows (see connection diagram): 

NEUTRAL (Blue)  

N      

EARTH (Green/Yellow) 
LIVE (Brown)  

L

Ensure that the connections are secure.

Fasten the lantern to the backplate using the domed nuts,
ensuring the wiring box seal is correctly in place.
Install the lightbulb (not supplied).
Install the glass panels, ensuring they are seated correctly.
Fit and secure the lantern lid. 

Isolation 

Switch

Summary of Contents for SLB44

Page 1: ...I N S T A L L A T I O N O P E R A T I N G I N S T R U C T I O N S 6 0 W P I R L A N T E R N L I G H T S L B 4 4 B l a c k S L W 4 5 W h i t e ...

Page 2: ...ith proof of purchase and it will be replaced free of charge Should you encounter any difficulty please contact our helpline on 020 8450 0515 3 YEAR GUARANTEE LAMP TYPE MAXIMUM 60w ES DETECTION ANGLE ADJUSTABLE 110 DETECTION RANGE ADJUSTABLE 8m WEATHERPROOF IP43 PIR SWITCHING MAXIMUM 60w TIME ON ADJUSTABLE 5sec 5min DUSK TO DAWN ADJUSTABLE SLB44 PIR LANTERN LIGHT BLACK ...

Page 3: ...ith proof of purchase and it will be replaced free of charge Should you encounter any difficulty please contact our helpline on 020 8450 0515 3 YEAR GUARANTEE LAMP TYPE MAXIMUM 60w ES DETECTION ANGLE ADJUSTABLE 110 DETECTION RANGE ADJUSTABLE 8m WEATHERPROOF IP43 PIR SWITCHING MAXIMUM 60w TIME ON ADJUSTABLE 5sec 5min DUSK TO DAWN ADJUSTABLE SLW45 PIR LANTERN LIGHT WHITE ...

Page 4: ...H COMPACT FLUORESCENT ENERGY SAVING LAMPS SECTION TWO SELECTING THE LOCATION The motion detector has a number of detection zones at various vertical and horizontal angles as shown see diagram A A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 1 8m Careful positioning of the sens...

Page 5: ...tenance purposes Remove the lantern backplate by unscrewing the brass domed nuts Remove the terminal block from its mount Punch through the knockouts in the backplate Mark the position of the fitting holes Drill the holes Insert the rawl plugs into the holes PIERCE PASS THE CABLE THROUGH THE GROMMET BEFORE PROCEEDING Attach the mounting plate to the wall using suitable screws Do not overtighten th...

Page 6: ...H Green Yellow LIVE Brown L Ensure that the connections are secure Fasten the lantern to the backplate using the domed nuts ensuring the wiring box seal is correctly in place Install the lightbulb not supplied Install the glass panels ensuring they are seated correctly Fit and secure the lantern lid Isolation Switch ...

Page 7: ...k tests are complete the unit can be switched to automatic operation The TIME setting controls how long the unit remains illuminated following activation after all motion ceases The minimum time fully anti clockwise is approx 5 seconds whilst the maximum time fully clockwise is approx 5 minutes Set the control to the desired setting between these limits The DUSK control determines the level of dar...

Page 8: ...ble for outdoor use Conforms to 73 23 EEC 89 336 EEC In the event of the cover glass shattering do not replace with normal household glass Contact the helpline for replacement details If you experience problems refer to Troubleshooting Guide If problems still exist do not immediately return the unit to store Telephone the Timeguard Customer Helpline 020 8450 0515 Qualified Customer Support Co ordi...

Page 9: ...ur property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section 3 Ensure no connections are loose Check the lamp If the lamp has failed replace Ensure that the lamp is seated correctly in the lampholder The level of ambient light in the area may be too bright to allow...

Page 10: ...nsitive More sensitive TOP VIEW 110º SIDE VIEW 8m 2 5m A B C Remove cover using a small screwdriver and lift up gently to reveal adjustment controls To replace cover simply line up and click back into position ...

Page 11: ...te SLB150 150W PIR Halogen Floodlight Black SLW150 150W PIR Halogen Floodlight White SLB2000 2000W PIR Light Controller Black SLW2000 2000W PIR Light Controller White SLB88 60W PIR Bulkhead Light Black SLW89 60W PIR Bulkhead Light White SLB44 60W PIR Lantern Light Black SLW45 60W PIR Lantern Light White ...

Page 12: ...Helpline 020 8450 0515 For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND or email csc timeguard com ...