background image

Ins
tallation & Oper

ating Ins

tructions

7 Day Digital Light Switch 

with Optional Dusk Start

Cat No. ZV700B

Summary of Contents for ZV700B

Page 1: ...I n s t a l l a t i o n O p e r a t i n g I n s t r u c t i o n s 7 Day Digital Light Switch with Optional Dusk Start Cat No ZV700B...

Page 2: ...weekly basis available at the press of a button There is a further option of starting an automatic lighting period at dusk but ending it with a timed OFF and a random option based around programmed t...

Page 3: ...low energy lighting Please refer to the specifications for rated loads Note the ZV700B is not designed for use with LED or discharge lighting Large Illuminated LCD display BS646 fuse rated at 2A Reset...

Page 4: ...earth wires connected to the wall box terminal If the switch is a 2 way switch used in conjunction with a second light switch it will have 3 wires In this case the wire originally connected to COM ter...

Page 5: ...Programming the Time and Date From first power up the screen should show Press Time and hold for 3 seconds Whilst holding the word hold will show Once in time programme mode the first option is day l...

Page 6: ...Month SET SET SET OFF Mo ON Prog Mo Tu We Th Fr SET Mo Tu We Th Fr Sa Su SET MODE Sa Su ON Prog SET OFF Prog Mo Tu We Th Fr SET SET Day Time 5 Use Adv or Mode to set the day Press Time to set the tim...

Page 7: ...the program mode This will scroll through the following programming options 24hr Mo Tu We Th Fr Sa Su 5 day Mo Tu We Th Fr 2 day Sa Su 7 day Mo Once the desired option is selected press Prog to move...

Page 8: ...ON programme 5 OFF press Prog twice programme 6 ON programme 6 OFF adding in times as required At any stage after programming an off time if Prog is pressed once there is the option of changing to th...

Page 9: ...il the programmed mode shows on the screen This will show the mode the ZV700B was programmed in It is possible at this stage to change this mode say from 24 hr to 5 2 using Adv or Mode but this may bl...

Page 10: ...only switches on when the light level drops The output will only come on if it is within a programmed on period Random mode R This uses the programmed ON OFF times On a random basis it can change the...

Page 11: ...720 hours by factory fitted internal battery Operating ambient temperature 10 C to 40 C Operating voltage 220 240 VAC Dusk start 10 LUX Terminations Suitable for 1mm sq and 1 5mm sq solid conductors a...

Page 12: ...uarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it to your supplier with proof of purchase...