background image

2

MEU11 & EMU11 24 Hour Modules

•  24 Hour Time Period – 4 ON/OFF programmes.

MEU17 & MEU17 7 Day Modules

•  7 Day Time Period – 6 ON/OFF programmes,  

daily, weekly, weekend or weekday options.

4. Contents

•  1x Timer module. 
•  1x Panel mount bezel. 
•  1x Tamper proof cover. 
•  4x Surface mount stand offs (length 10mm). 
•  2x Panel mount bolts. 
•  2x  Self-tapping screws (No. 4 x 5/8in)  

for panel mount bolts. 

•  2x  Self-tapping screws (No. 6 x 3/8in)  

for attaching bezel to EMU11. 

5.   Installation

Summary of Contents for EMU11

Page 1: ...l l a t i o n O p e r a t i n g I n s t r u c t i o n s Timer Modules MEU11 24 Hour Module MEU17 7 Day Module Without Housing EMU11 24 Hour Module EMU17 7 Day Module With Housing Giving panel mounting...

Page 2: ...allation of this timer module and install in accordance with the current IEE wiring and Building Regulations Check that the total load on the circuit before attempting to use the time module for your...

Page 3: ...F programmes daily weekly weekend or weekday options 4 Contents 1x Timer module 1x Panel mount bezel 1x Tamper proof cover 4x Surface mount stand offs length 10mm 2x Panel mount bolts 2x Self tapping...

Page 4: ...and secured in place by the use of the 2x No 6 x 3 8 in self tapping screws provided as shown in figure 3 When selecting a position for the unit bear in mind that a clearance behind the front panel su...

Page 5: ...nto the panel and tighten up the 2x No 4 self tapping screws The ears on the bolts will rotate as you tighten to clamp the unit to the panel Surface Mounting The EMU11 17 without bezel can be surface...

Page 6: ...5 6 Connection All models Single Resistor PSU MEU11 MEU17 only Two Resistor PSU gives Optimum EMC Performance MEU11 MEU17 only...

Page 7: ...with power derived from the mains Type RP330048 or RP331048 Changeover contracts In these configurations the relay pulls in at 47V and is held at above 24V with mains voltages down to 200V EMU11 and...

Page 8: ...d with a 330nF X 250V AC capacitor instead of the 220nf capacitor shown and a 1 3W zener must be connected between pins 1 and 2 of the module In all cases the zener is 47V and its cathode is connected...

Page 9: ...OFF programme times and to review them once set Output Status showing unit either ON or OFF Output Status showing unit either ON or OFF Change Button sets Hours and Minute times and self cancelling o...

Page 10: ...gramming process Each time the Program button is pressed the display will flash either the hours or the minutes in turn starting with the clock then the first ON time first OFF time second ON time and...

Page 11: ...urrent day Once this is complete press the Program button to move to setting the clock You are now in the clock setting mode at the beginning of the programme sequence To set the hour for the clock pr...

Page 12: ...set individual days Press the Change button to select the hour you require for the programme Press the Program button to confirm the hour and advance to the minute setting Press the Program button on...

Page 13: ...it the program mode at anytime press and hold the Program button until you are back at the current time IMPORTANT Once programming has been completed the unit will show an OFF status by default If you...

Page 14: ...ogramme times 7 7 Clearing Programmes Any individual programme can be cancelled by clearing its ON and OFF time Follow the steps as mentioned in section 7 5 Program Review until you reach the program...

Page 15: ...f of purchase is required in all cases For all eligible replacements where agreed by Timeguard the customer is responsible for all shipping postage charges outside of the UK All shipping costs are to...

Page 16: ...a product brochure please contact Qualified Customer Support Co ordinators will be on line to assist in resolving your query If you experience problems do not immediately return the unit to the store...

Reviews: