1
1. General Information
These instructions should be read carefully
and retained for further reference
and maintenance.
2. Safety
• Before installation or maintenance,
ensure the mains supply to the time switch is
switched off and the circuit supply fuses are
removed or the circuit breaker turned off.
• It is recommended that a qualified electrician
is consulted or used for the installation of this
time switch and install in accordance with the
current IEE wiring and Building Regulations.
• Check that the total load on the circuit
including when this time switch is fitted
does not exceed the rating of the circuit cable,
fuse or circuit breaker.
3. Technical Specifications
• 230V AC 50 Hz
• Switch Rating:
16A Resistive (3.68kW)
Immersion Heaters
2400W incandescent
and halogen lighting
750W fluorescent
lighting
100W Compact
fluorescent & LED lighting
The LED switching capabilities of this product
can be increased to 200W by the addition of
the Timeguard ZV900 Automatic switch load
controller – sold separately.
• Switch Type:
16A relay
• Voltage free contact: NTT04 only
• Contact Type:
Normally Open