background image

TMS6002 
USER MANUAL 

Ref :  MN06127 

Date :  2019-03-27

 

Issue :  A1 

Page:  12/18 

 

Tous droits réservés © TimeLink microsystems

 

The second line shows the position of the antenna connected to the equipment. 

 

Available actions from this screen are: 

 

A  long  press  on  the  red  button  excludes  or  includes  the  GNSS  source  into  the  list  of  available  time 
sources. 

 

A  GNSS  Coldstart  is  achieved  by  pressing  successively  red  button,  left  arrow,  left  arrow,  right  arrow, 
right arrow, green button. Once a cold start has been done, the equipment must be switched OFF and 
ON.  

 

3.3.3.1.

 

IRIGB SCREEN 

IRIG-B  time is not available               

Type: standard status : no signal          

Sample screen for IRIGB time source (no signal in that case) 

 

 

A  long  press  on  the  red  button  excludes  or  includes  the  IRIGB  source  into  the  list  of  available  time 
sources. 

 

3.3.4.

 

OSCILLATOR SCREEN 

This screen gives information about  

 

the measurement of the phase differences between the internal 1PPS and the 1PPS of the time source

 

 

the computed frequency stability estimator

 

Est. Stab.=+1.023e-11             PH/TR  

            PPS/GPS = +012ns 

Sample screen of the oscillator 

The first line gives the stability estimator, and the mode (here active PHASING/TRACKING). 

The second line indicates the estimation of the phase difference between the internal generated 1PPS and the 
1PPS of the reference time source. 

 

Est. Stab.=+1.023e-11              HEAT  

         PPS/GPS = +012ns          10s 

Sample screen of the oscillator during the heating period 

 

First line indicates that the oscillator is heating. 

Second line indicates the remaining time for the end of heating. 

Summary of Contents for MN06127

Page 1: ...Tous droits r serv s TimeLink microsystems TMS6002 USER MANUAL Reference MN06127 Issue A1 Date 2019 03 27...

Page 2: ...TMS6002 USER MANUAL Ref MN06127 Date 2019 03 27 Issue A1 Page 2 18 Tous droits r serv s TimeLink microsystems Version change Issue Date Description A1 2019 03 27 Original issue...

Page 3: ...NG UP 9 3 2 LEDS 9 3 3 SCREENS 10 3 3 1 MAIN SCREEN 10 3 3 2 ALARMS SCREEN 11 3 3 3 SOURCE SCREEN 11 3 3 3 1 GNSS SCREEN 11 3 3 3 1 IRIGB SCREEN 12 3 3 4 OSCILLATOR SCREEN 12 3 3 5 EQUIPMENT INFORMATI...

Page 4: ...riority selection amongst them The equipment will automatically switch from one to the other source if the current source is not usable anymore 1 1 FRONT AND BACK PANEL The front panel of the device h...

Page 5: ...ARD Power supply input s CEE 2P E socket with integrated filter and ON OFF switch Integrated back up power supply 85 to 265V AV 47 60Hz Consumption 10W at 230VAC 50 Hz NTP Service RJ45 connector named...

Page 6: ...TION The proper functioning of the equipment requires setting the configuration parameters with consistent values These settings are located on an SD card inserted in the back of the equipment The par...

Page 7: ...ty of the source compare to the others 1 is highest priority Mandatory 1 1 2 3 IRIGB_IN Select the priority of the source compare to the others 1 is highest priority Mandatory 2 1 2 3 LOCAL Select the...

Page 8: ...can be activated Mandatory N Y or N BEIDOU Enable or disable BEIDOU constellation Only 2 constellations can be activated Mandatory N Y or N Note any change to the default constellation must be followe...

Page 9: ...5 notrust authenticated 3 HOW TO GET STARTED 3 1 POWERING UP The equipment power up when the power is applied to the unit and the ON OFF switch is turned ON 3 2 LEDS On the front panel a group of thre...

Page 10: ...efault screen It provides a synthesis of the operation of the equipment The displayed information is the following current UTC date and time name of the selected time source GNSS or LOCAL quality of t...

Page 11: ...hen multiple alarms are up the left and right arrow keys can be used to navigate around them The number of alarms is shown is the upper right corner with the syntax X N where X is the X th alarm out o...

Page 12: ...no signal in that case A long press on the red button excludes or includes the IRIGB source into the list of available time sources 3 3 4 OSCILLATOR SCREEN This screen gives information about the meas...

Page 13: ...e the software modify the password of a user restart or stop the equipment connect as root The default password for both accounts is timelink 3 4 1 CHANGE PASSWORD To change the password for a user us...

Page 14: ...change its identity to root To do this type tools su and enter the root password 3 5 SERIAL CONSOLE ACCESS Access to the system can also be made from the Console port by connecting a terminal emulator...

Page 15: ...ccuracy The Time sources section provides control over the available time sources as shown below A right click on the source allows excluding or including the selected source 4 2 SNMP MONITORING The m...

Page 16: ...card reader of a PC Use a text editor to modify the user ini file The SD card can then be located back into the equipment which needs to be powered on Important note Depending on the used text editor...

Page 17: ...TMS6002 USER MANUAL Ref MN06127 Date 2019 03 27 Issue A1 Page 17 18 Tous droits r serv s TimeLink microsystems 3102 GNSS time is different from internal...

Page 18: ...TMS6002 USER MANUAL Ref MN06127 Date 2019 03 27 Issue A1 Page 18 18 Tous droits r serv s TimeLink microsystems Fin du document...

Reviews: