TMS6002
USER MANUAL
Ref : MN06127
Date : 2019-03-27
Issue : A1
Page: 15/18
Tous droits réservés © TimeLink microsystems
The top section is an active remote management of the front face and allows browsing through the equipment
menu remotely.
Long press is replaced by “CTRL” and button click.
•
The top left part allows checking and controlling the equipment.
•
The oscillator section provides information on the stability accuracy.
•
The Time sources section provides control over the available time sources as shown below
A right click on the source allows excluding or including the selected source.
4.2.
SNMP MONITORING
The monitoring of the equipment can be made using the SNMP v2c protocol. See the provided MIB file for
complete description of the information that can be monitored.
The community configuration is located in the file
'/config/etc/snmp/snmpd.conf'
. The default
name for read-only is
'public'
and read-write is
‘private’
.
The MIB root OID is:
1.3.6.1.4.22641.100
.
Active
control
Display adjusts to arrow
selection on the right