PHYSICAL INSTALLATION OF EQUIPMENT
The equipment is intended to be installed into a 19" cabinet. It is recommended to connect the equipment to
the protective ground of the cabinet via the ground stud on the left rear of the equipment.
2.2.
CONNECTIONS
The following connections must to be made:
•
Connect the equipment to the AC power via the supplied AC cord.
•
Connect the mechanical chassis ground to the cabinet ground.
•
Connect the GNSS antenna cable to the antenna input of the equipment.
•
Connect the equipment to the remote management network ("LAN" connector) with a RJ45 network
cable.
Important:
Power the equipment only after all connections have been made
.
2.3.
CONFIGURATION
The proper functioning of the equipment requires setting the configuration parameters with consistent values.
These settings are located on an SD card inserted in the back of the equipment.
The parameters available to the user are located in the
'user.ini'
file. When inserted into a PC, the
'user.ini'
file
is located in the
'TMS6002'
directory of the SD card. On the equipment, this file is located in the
'/config'
directory.
The following table lists the parameters according to their location in the configuration space. The procedure to
change the settings is described in the maintenance chapter of this document.
Important:
Please do not modify files other than those listed below under penalty of breaking the equipment’s
operation, except if the support staff of Timelink microsystems invites you to do so.
2.3.1.
General settings
These settings are located in the
'TMS6002/user.ini
'
file of the SDCARD.
Only the parameters listed below can be modified, contact TIMELINK for other needs.