5
1.3 Markings
■
The C-Power is clearly marked with a label on the drive system and a label on the C-Power LV-unit.
■
CE mark is located on the drive unit and the C-Power LV-unit.
1.4 Intended
Usage
The Timken C-Power:
■
Immediately supplies all lubrication points with lubricant, at a pressure buildup of max. 360 psi (25 bar).
■
Supply is precise and independent of temperature.
■
Can be used for all lubrication points.
■
Should only be connected to and used with original lubrication tubes from Timken.
■
Is intended for use on machinery and equipment.
■
Should not be used for any inappropriate purpose.
■
Is only to be used under recommended operating conditions.
■
Is only to be used with the recommended settings and variations.
Any other usage, setting, addition and/or variation is considered inappropriate.
1.5 Legal
Requirements
Liability
■
The information, data and tips contained in this operating manual were current as of the printing date.
No claims for the Timken C-Power that were already delivered can be made based on the
following information, pictures and descriptions.
■
Timken cannot be held liable for damages and malfunctions caused by:
●
Inappropriate usage.
●
Unauthorized alterations to the drive system or the C-Power LV-unit.
●
Inappropriate operations on or with the lubricator.
●
Incorrect operation and settings of the lubricator.
●
Incorrect settings of time and size of the lubricator.
●
Disregarding the operating manual.
Warranty
■
Warranty terms and conditions: see terms and conditions of sale and delivery pertaining to Timken.
■
Immediately lodge any warranty claims with your local supplier.
■
The warranty expires in all instances where no liability claims can be enforced.