UM-16
4 Installation instructions
Fig. 19
Fig. 20
Fig. 21
The electrical panel is supplied with the robot, not with the CTU.
Make sure that all cables are connected;
- Small
BLACK
cable - electrical panel power (220 V),
-
BLUE
cable - High-Flex robot power and signal cable
- WHITE cable - Ethernet network connection cable between
the electrical cabinets of CTU and the robot.
Depending on the order the WHITE cable will be supplied in 6
or 12 meters length.
The
BLUE
High-Flex robot power and signal cable is already
inserted into the cable carrier in the axis chains. It is supplied
6m or 12m long based on CTU stroke (Page UM-13 for con-
necting the robot).
BLUE cable
High-Flex robot
power and signal
cable inlet
into CTU
Connecting the robot
Power down the system while any opera-
tion of assembly/disassembly is performed.
The UR robot operates even if the CTU con-
trol cabinet is turned off.
Pressing the emergency button of the robot
stops the axis as well.
Summary of Contents for ROLLON CTU 220-1I
Page 2: ......
Page 44: ...UM 42 Notes Notes...
Page 45: ...UM 43 Cobot Transfer Unit Notes...
Page 46: ...UM 44 Notes Notes...