background image

 

Hand Control Programming-TDH27P 

 

 

 

Version 1 July 2021 

1  of  12 

 

 

 

 

 

20210727 

 

User  Manual 

Hand Control 

Programming- 

TDH27P 

Summary of Contents for TDH27P

Page 1: ...Hand Control Programming TDH27P Version 1 July 2021 1 of 12 20210727 User Manual HandControl Programming TDH27P...

Page 2: ...the Height 6 4 Setting the Memorized Position 6 5 Setting the Upper and Lower Height Limit 7 6 Presetting the Desk Starting Height 8 7 Lock Unlock 8 8 Switching Metric and Imperial Unit 9 9 Adjusting...

Page 3: ...claimer This user manual is ONLY for generic TiMOTION products Manufacturers may have altered product settings causing them to differ from this user manual Please contact the manufacturer for a revise...

Page 4: ...Hand Control Programming TDH27P Version 1 July 2021 4 of 12 1 User Interface Guide 3 digit height display Up and down buttons Safety lock button Memory setting buttons...

Page 5: ...ue pressing the buttons until both columns are in the lowest position When finished with the reset the control box will make a beep sound and the buttons can be released 2 When finished with the reset...

Page 6: ...mum of 2 memory positions How to memorize a position 1 Adjust the desk to the desired height 2 Press the preferred memory button 1 or 2 with either or for 2 seconds Once the display shows P1 or P2 the...

Page 7: ...being set 2 Repeat instructions 2 4 above to disable the upper limit setting C Setting the lower height limit 1 Adjust the desk to the preferred lower height limit 2 Press and buttons together for les...

Page 8: ...s 2 Adjust the starting height number with the or button 3 After 10 seconds the display will stop flashing and this will confirm that you have successfully set the starting height 7 Lock Unlock 1 Lock...

Page 9: ...5 seconds 2 The digital display will show C I If no further instruction is input within 5 seconds the system reverts to normal operation mode How to choose a metric unit Press button 1 the digital dis...

Page 10: ...TCS1 is connected with the control box which has built in T touch both sensitivities will be changed simultaneously Level 0 1 2 3 4 5 6 7 8 9 Sensitivity Cancel T touch Less sensitive Default More sen...

Page 11: ...ng E00 Not reset completely E01 Overuse protection E02 Unbalance protection E03 Anti collision E04 T touch Protection E11 M1 Motor over current protection E12 M2 Motor over current protection E13 M3 M...

Page 12: ...o buttons are pressed within 25 seconds Press any button to light up the display again The system goes into 0 1W standby mode Note 6 if no buttons are pressed within 30 seconds Long pressing any butto...

Reviews: