8  of  12 

 

6.

 

Presetting the Desk Starting Height   

(1)

 

Press 

  button until the desk reaches its lowest position and then release 

  button. Re-press 

 

button again for 5 seconds, and the digital display will flash for 10 seconds.   

(2)

 

Adjust the starting height number with the 

  or 

  button.   

(3)

 

After 10 seconds, the display will stop flashing, and this will confirm that you have successfully set the 

starting height.   

7.

 

 

Lock / Unlock 

(1)

 

Lock: Press the “lock” button for one second or do not touch any buttons for 20 seconds, then the image 

will be shown on the display to indicate that the lock was completed successfully (as below image). 

(2)

 

Unlock: Hold the “lock” button for 3 seconds to unlock the hand control. 

 
 

 

   

 

Summary of Contents for TDH27P

Page 1: ...Hand Control Programming TDH27P Version 1 July 2021 1 of 12 20210727 User Manual HandControl Programming TDH27P...

Page 2: ...the Height 6 4 Setting the Memorized Position 6 5 Setting the Upper and Lower Height Limit 7 6 Presetting the Desk Starting Height 8 7 Lock Unlock 8 8 Switching Metric and Imperial Unit 9 9 Adjusting...

Page 3: ...claimer This user manual is ONLY for generic TiMOTION products Manufacturers may have altered product settings causing them to differ from this user manual Please contact the manufacturer for a revise...

Page 4: ...Hand Control Programming TDH27P Version 1 July 2021 4 of 12 1 User Interface Guide 3 digit height display Up and down buttons Safety lock button Memory setting buttons...

Page 5: ...ue pressing the buttons until both columns are in the lowest position When finished with the reset the control box will make a beep sound and the buttons can be released 2 When finished with the reset...

Page 6: ...mum of 2 memory positions How to memorize a position 1 Adjust the desk to the desired height 2 Press the preferred memory button 1 or 2 with either or for 2 seconds Once the display shows P1 or P2 the...

Page 7: ...being set 2 Repeat instructions 2 4 above to disable the upper limit setting C Setting the lower height limit 1 Adjust the desk to the preferred lower height limit 2 Press and buttons together for les...

Page 8: ...s 2 Adjust the starting height number with the or button 3 After 10 seconds the display will stop flashing and this will confirm that you have successfully set the starting height 7 Lock Unlock 1 Lock...

Page 9: ...5 seconds 2 The digital display will show C I If no further instruction is input within 5 seconds the system reverts to normal operation mode How to choose a metric unit Press button 1 the digital dis...

Page 10: ...TCS1 is connected with the control box which has built in T touch both sensitivities will be changed simultaneously Level 0 1 2 3 4 5 6 7 8 9 Sensitivity Cancel T touch Less sensitive Default More sen...

Page 11: ...ng E00 Not reset completely E01 Overuse protection E02 Unbalance protection E03 Anti collision E04 T touch Protection E11 M1 Motor over current protection E12 M2 Motor over current protection E13 M3 M...

Page 12: ...o buttons are pressed within 25 seconds Press any button to light up the display again The system goes into 0 1W standby mode Note 6 if no buttons are pressed within 30 seconds Long pressing any butto...