background image

………………………………………………………………

……………

www.tinytag.info

www.tinytag.info

www.tinytag.info

www.tinytag.info         

sales@tinytag.info

sales@tinytag.info

sales@tinytag.info

sales@tinytag.info    

………………………………………………………………

……………

.

 

Thermocouple

Logger

 

Further Information

Further Information

Further Information

Further Information    

 
Further information on Tinytag data loggers, software and accessories can be 
found on our web site at:

    

    

www.tinytag.info

www.tinytag.info

www.tinytag.info

www.tinytag.info

 

 
If you should have any further questions, please contact your distributor or: 
    

Gemini Technical Support

Gemini Technical Support

Gemini Technical Support

Gemini Technical Support    

t: +44 (0)1243 813009 

e: help@tinytag.info 

Approvals

Approvals

Approvals

Approvals    

 
Gemini Data Loggers (UK) Ltd. operates a Business Management System which 
conforms to ISO 9001 and ISO 14001.  

Battery Information

Battery Information

Battery Information

Battery Information    

 
The battery fitted in this product is a single cell containing less that 1g of lithium 
and meets the requirements of the UN Manual of Tests and Criteria, Part III, 
Subsection 38.3.   
 
Recommended Battery Types

Recommended Battery Types

Recommended Battery Types

Recommended Battery Types 

SAFT LS14250,  

 

 

 

 

Tekcell SBAA02P or  

 

 

 

 

Eve ER14250 

 

 

 
The logger will operate with other ½AA 3.6V Lithium batteries but performance 
cannot be guaranteed. 
 
Replacement Interval 

Replacement Interval 

Replacement Interval 

Replacement Interval  

Annually 

 
Before replacing the battery the data logger must be stopped. 
 
Data stored on the logger will be retained after a battery is replaced.  

9

8

0

0

-0

1

1

6

Is

su

e

 4

 (9

th

 A

u

g

u

st

 2

0

1

9

)  

LED Flash Patterns

LED Flash Patterns

LED Flash Patterns

LED Flash Patterns    

 

When logging, status LEDs on the front of the logger will flash as follows: 
 

Flash Pattern

Flash Pattern

Flash Pattern

Flash Pattern    

    

    

Indication

Indication

Indication

Indication    

 
A green flash every 4 seconds 

Logging 

A green flash every 8 seconds 

Waiting to log (set for a delayed start)   

A red flash every 4 seconds 

Alarm limit breached 

 
For more information on the alarms and how they work, please see the Tinytag 
Explorer quick start guide and help file. 

Physical Specification

Physical Specification

Physical Specification

Physical Specification    

 
Logger

Logger

Logger

Logger    
 
IP Rating

IP Rating

IP Rating

IP Rating  

 

 

IP51  

Working Temperature  Range

Working Temperature  Range

Working Temperature  Range

Working Temperature  Range    

-40 to +85°C (-40 to +185°F) 

Case Dimensions

Case Dimensions

Case Dimensions

Case Dimensions    
 

Height

Height

Height

Height   

 

42mm / 2.83” 

 

Width

Width

Width

Width      

 

60mm / 2.36” 

 

Depth

Depth

Depth

Depth      

 

33mm / 1.30” 

Weight

Weight

Weight

Weight   

 

 

65g / 2.29oz 

 
Supplied Type K Thermocouple

Supplied Type K Thermocouple

Supplied Type K Thermocouple

Supplied Type K Thermocouple    
 
Temperature Range

Temperature Range

Temperature Range

Temperature Range    

    

-100 to +250°C (-148 to 482°F) 

Lead length 

Lead length 

Lead length 

Lead length  

 

 

1m / 39.37” 

Warranty

Warranty

Warranty

Warranty    

 
This product carries a manufacturing defects warranty of 12 months from the date 
of purchase. Units returned under warranty will be repaired or replaced at the 
manufacturer’s discretion. This warranty does not cover mishandling, modification 
or battery replacement and is subject to the standard Terms and Conditions of 
Sale, a copy of which is available on request. 
 
The equipment/goods are sold “as is” and with “all faults” (applies in USA). 

The equipment/goods are sold “as is” and with “all faults” (applies in USA). 

The equipment/goods are sold “as is” and with “all faults” (applies in USA). 

The equipment/goods are sold “as is” and with “all faults” (applies in USA). 
Claims under warranty should be referred to the point of sale.

Claims under warranty should be referred to the point of sale.

Claims under warranty should be referred to the point of sale.

Claims under warranty should be referred to the point of sale.    

Disposal

Disposal

Disposal

Disposal    

 
Data loggers, accessories and batteries should be disposed of at 
organised facilities, where available, in compliance with local 
regulations. 
 
In accordance with the WEEE directive Gemini Data Loggers (UK) Ltd. 
will take back and dispose of any equipment purchased directly.  
Equipment not purchased directly should be returned to the point of 
sale for disposal. 

Notes

Notes

Notes

Notes    

 
If used at low temperatures the data logger should be allowed to warm to room 
temperature before it is opened to avoid condensation forming inside it. 
 
The IP51 rating is valid only when the logger’s connector cover is fitted and the 
unit is orientated with it’s hanging tab uppermost.  
 
 
Trigger Start 

Trigger Start 

Trigger Start 

Trigger Start     
 
The trigger start option allows a logger to be set up as required and then started 
at a later time with a magnet.  The position of the trigger start switch is indicated 
by the • • • marking on the back of the logger.  When the "Wait until trigger 
event" option is  selected in the Tinytag Explorer software the green LED on the 
logger will flash once every eight seconds to indicate that it is waiting to start.  
When a magnet is swiped past the • • • marking, the green LED will light to 
indicate the switch is closed.  After the magnet has been removed, the green LED 
will flash every four seconds to indicate that the logger is recording. 

Calibration

Calibration

Calibration

Calibration    

 
This logger is configured to meet Gemini’s quoted specification during its 
manufacture. 
 
We recommend that the calibration of the logger should be checked annually 
against a calibrated reference meter. 
 
A certificate of calibration, traceable to national standards, can be supplied for an 
additional charge either at the point of purchase, or if the logger is returned for a 
service calibration. 

Reviews: