background image

INSTALLATION MANUAL

Our Luna Outdoor Bell Panel can indicate the 

hotel room number day and night and features a 

touch bell button and 3 indicators for Do not disturb 

(DND), Make up room (MUR), and Laundry.

Models: LUNA-OUT-3S-BELL, LUNA-OUT-3S-BELL-RF

PRODUCT INFORMATION

6

58921 79726

6

BARCODE (UPC-A)

6

58921 79724

2

BARCODE (UPC-A)

PRODUCT SPECIFICATIONS

Touch

Active area

1 button for bell

Touch Type

Capacitive 

Input

Using Panel Addition

4 Digital Inputs

IF used the RF type

RF Reader (optional Frequency)

Output

Low current relay

3 Relay Output 3A/5A

TIS Bus

Number of devices on 1 line

Max. 64

Bus voltage

12-32 V DC

Current consumption

<25 mA / 24 V DC

Operating and display 

elements

touch buttons

1 touch button

Backlight  

3 RGB indi Room number white LEDs

Functions

Bell Press

Touch Button

Access Control (RF type)

RF Reader with Relay output  

Dimensions

Width × length × height

129mm × 13mm × 90mm (94mm peak) 

Housing

Materials 

PC fire proof / Glass in front

Casing color

Silver plating frame, Black Glass 

Internal Parts color

Black & White

IP rating

IP 50

Summary of Contents for RF-BELL-3S-OUT-LUNA

Page 1: ...nel Addition 4 Digital Inputs IF used the RF type RF Reader optional Frequency Output Low current relay 3 Relay Output 3A 5A TIS Bus Number of devices on 1 line Max 64 Bus voltage 12 32 V DC Current c...

Page 2: ...ith four twisted pairs Configure devices in a Daisy Chain Do not cut or terminate live data cables Warranty There is a two year warranty provided by law The hologram warranty seal and product serial n...

Page 3: ...d TIS Logo is a Registered Trademark of Texas Intelligent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to chan...

Page 4: ...BUS wire to the Panel Addition Connect the other connection if needed between wall services switches to the digital inputs of the hotel panel as per the following diagram R7 R8 C2 VD4 L1 089 E3 Q4 C20...

Page 5: ...C2 VD4 L1 089 E3 Q4 C20 C26 DND CLEAN LUNDARY CARD GND RIN ROUT R1 C1 E1 R3 VD6 E2 F3 D3 N1 24V D D GND C4 Q1 VD1 F1 F2 R2 ac ac REMOVE AFTER WASHING HF04 227A ac GND white orange white brown D white...

Page 6: ...igent System LLC in the United States of America This company takes TIS Control Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m LU...

Page 7: ...OOR BELL SERVICE PANEL USER MANUAL The hotel service light will light up to a indicate service request such as Laundry Make Up Room or Do Not Disturb DND The backlit color can be set from the software...

Page 8: ...ontrol Ltd in other countries All of the Specifications are subject to change without notice w w w t i s c o n t r o l c o m LUNA HOTEL OUTDOOR BELL SERVICE PANEL TROUBLESHOOTING The panel buttons LED...

Reviews: