1
2
3
4
5
Continued Table
8
ХТ2/8
EXIT
Signal is generated by
controller when “PANIC”
function is activated
ХТ3/1
OPTO1
ENTRY
It is used for acquisition of
data about the turnstile
rotor position
1) Logical «0»
(0 ÷ 2,2) V
2) Logical «1»
(3 ÷ 5) V
3)Active level of
-
signal (Factory
setting)
Logical «0»
4) Voltage on open
input < 5 V
ХТ3/2
OPTO2
ENTRY
ХТ3/3
OPTO3
ENTRY
ХТ3/4
SGN1
ENTRY Not applicable
ХТ3/5
SGN2
ENTRY
Selection of turnstile
modification
ХТ3/6
SGN3
ENTRY Not applicable
ХТ3/7
SGN4
ENTRY Not applicable
ХТ3/8
INDAR
EXIT
It is used for the turnstile
LED display control
1) Type of output -
open collector
2) Peak voltage on
privacy key 30 V
3) Peak current of
public key 2A
INP1 («
PANIC
»)
ХТ3/9
INDAG
EXIT
ХТ3/10
INDBR
EXIT
ХТ3/11
INDBG
EXIT
ХТ3/12
PSW1
EXIT
1) Type of output -
open emitter.
2) Voltage on output
in ON state 12 V.
3) Peak current
consumed from
output 1 A.
4) Resistance of
public key 0.25 Ohm
ХТ3/13
PSW2
EXIT
Not applicable
4) Resistance of
public key 0,1 Ohm
Not applicable