2.3.2.2 After the turnstile is inspected it is ready for long-term operation.
2.4
Contingency actions
For emergency human escape (in case of fire, acts of God etc.) and enabling free access the
turnstile to be unlocked from control panel by issuing the relevant command. Antipanic device to
be used for full opening of access way.
The antipanic device (
See Fig. 6
) is automatically activated when the turnstile is deenergized
(Failsafe), and in this case a barrier rod can't be returned to its initial position during the active
panic mode.
Barrier rod is dropped and access way is cleared when the "PANIC" button is pushed on control
panel and hold for more than 7 seconds or when signal is sent to the relevant input (
in1
) of the
turnstile controller.
After the signal is deactivated from the input (
in1
) or deactivation of the panic mode from control
panel, a barrier rod is automatically reset to its initial position.
3
MAINTENANCE
3.1
General guidelines
3.1.1 Commissioning and subsequent maintenance of the turnstile to be performed
only by the staff to be in charge of the turnstile.
3.1.2 The turnstile to be serviced only by the staff having the relevant electrical
safety qualification level according to the national requirements.