7
Continued Table 3
1
2
3
disturbing normal operation of the
equipment installed in turnstiles
Installation site
In enclosed spaces in the absence of
direct impact of precipitations and
solar radiation
Operating position
Vertical, deviation from vertical
position no more than 1º to any side
is acceptable
1.1.5
Reliability indices:
– mean time to repair (without delivery time of spare parts, tools and accessories) – at most
6 hours;
– mean time to failure – at least 1 500 000 accesses;
– mean service life between overhauls – at least 10 years.
1.2
Specifications
The key parameters of the turnstile are specified in Table 4.
Table
4
Parameter description
Unit measure
Parameter
value
Minimum traffic flow capacity in free access mode
man/min.
60
Minimum traffic flow capacity in single access mode
man/min.
25
Maximum access way width
mm
600
mm
Power supply voltage:
–
AC power supply (primary)
V
Hz
100
240
~ 50/60
–
DC power supply (secondary)
V
12
Maximum power consumption
W
55
Index of protection according to
EN 60529
-
IP41*
1.3
Configuration and Scope of Delivery
1.3.1
The servo-operated waist-high turnstile design
i
ncludes the following key
devices and components
(
See Fig.
1
):