31
lubrication of all rubbing stop levers, wheel and pinion teeth of the turnstile control
mechanism at least monthly with lubricant OKB-122-7 according to GOST 18179-
72 or LITOL 24, Ciatim or engine oil.
Table 11 -
Periodic maintenance by technical staff
Component
Period
Action
Fixation screws
6
months
Checking/Tightening
Mechanical screws
6
months
Checking/Tightening
Actuator
12
months
Control
Controller
12
months
Ch Cleaning
Position sensors
6
months
Ch Cleaning
Cable joints and sockets
12
months
Control
Locking device
6
months
Ch Cl
Lubrication
WARNING:
The turnstile should not be washed with water under pressure. There are no
user-serviceable parts inside the turnstile. Do not attempt to perform repair
such as lubrication, component replacement and adjustment inside the device.
All such works to be performed only by the qualified technical personnel!
4 ROUTINE MAINTENANCE
4.1 General guidelines
Minor malfunctions of the turnstile are listed in Table 12 and to be remedied by the
customer. More complicated malfunctions to be remedied by the
manufacturer’s representative.
IMPORTANT:
INSPECTION, CLEANING, REPAIR OF THE TURNSTILE COMPONENTS
TO BE PERFORMED ONLY AFTER THE TURNSTILE IS DEENERGIZED!
4.2 Possible malfunctions
Possible malfunctions of the turnstile and their remedies are listed in Table 12.
Table 12
Description of the Fault
Possible Cause
Recommended Action
The turnstile does not
work even if the power
plug is on.
No AC power supplied to
unit.
Loose power cable
Faulty power supply unit
Restore AC power.
Connect power cable.
Replace power supply unit
Rotor(arms) is free rotate
when power is ON
Damaged the wires
No DC power +12V
Faulty power supply unit
The PCB.201.01.00.00 is
faulty
Check wires
Check power supply unit
Replace power supply unit
Replace PCB.201.01.00.00