28
9) The length of cable free ends to be at least 1 m to provide their entry termination and
connection to the relevant
terminals in the turnstile rack
(on control desk).
10) The cable outlet
point to be to be aligned with
the hole on the turnstile
frame mounting plate.
11) To provide access
to fixation holes and terminal
blocks from both sides of
cabinet it is required to:
1.
–
remove the turnstile
lid by unscrewing screws
on butt ends (See Fig. 16);
2. - remove lining by
by unscrewing screws on the
turnstile frame;
3. - The turnstile to be
installed upright at the
prepared location;
- Cables to be pulled
through
available
service
hole in the turnstile rack
bottom end part by reclining
the turnstile;
4. - align fixation holes
at the turnstile bottom plate
with the prepared surface
holes
according
to
the
marking shown in Fig.13;
The turnstile to be
fixed by means of anchors
included in the scope of
delivery
Fig. 16 - General view of the «JETPAN-1» turnstile cabinet
installation