34
Table 8
Detergent description
Manufacturer
Country of origin
Stainless steel cleaning spray “Stainless
Steel Cleaner And Polish”
3M
Group of European
companies
Cleaning fluid “Well Done”
Well Done
Hungary
Stainless steel products and other metals
cleaner “XANTO STEEL 3in1”
XANTO
United Kingdom
«Dr.BECKMANN»
Dr.Beckmann
Germany
Cleaning
solution
“Reinex
Edelstahlreiniger”
Reinex
Germany
Cleaning spray “Stainless steel cleaner”
Onish
United Kingdom
3.3.3 Periodic maintenance for the purpose of defect detection and remedy is performed at
least twice a year and includes as follows:
−
visual inspection of the turnstile body, actuating mechanism and other components
for absence of external damages (corrosion, warps and other mechanical defects
and pollutions);
−
visual inspection of connecting, network and earthing cable condition;
−
verification of the turnstile performance;
−
during manual control in the modes specified in Table 7 or when identification
cards are used;
−
verification of reliability of the turnstile screw joints and earthing connections;
4 ROUTINE MAINTENANCE
4.1 General guidelines
Minor malfunctions of the turnstile are listed in
Table 9
and to be remedied by the customer.
More complicated malfunctions to be remedied by the manufacturer’s representative.
IMPORTANT:
INSPECTION, CLEANING, REPAIR OF THE TURNSTILE COMPONENTS TO
BE PERFORMED ONLY AFTER THE TURNSTILE IS DEENERGIZED !
4.2 Possible malfunctions
Possible malfunctions of the turnstile and their remedies are listed in Table 9.
Table 9
Description of the Fault
Possible Cause
Recommended Action
1
2
3
Turnstile does not
operate when
energized
There is no mains power
supply.
Idle power cable.
Power supply unit is out of
order.
AC power to be recovered.
Power supply cable to be connected.
Power supply unit to be replaced..