35
Continued Table 9
1
2
3
Blade does not open
Belt is damaged.
Magnetic sensor is
adjusted improperly.
Magnetic sensor is out of
order.
Turnstile does not obtain
actuation signal from ACS
Magnetic sensor to be replaced.
Belt to be replaced.
Magnetic sensor to be adjusted or
PCB to be replaced.
Proper connection of ACS to input -
output terminals on controller board to
be checked. Availability of actuation
signal from ACS to be checked.
Blade knocks
Magnetic sensor to be
checked.
Magnetic sensor to be adjusted or PCB
to be replaced.
Control panel sends
sound signal
"communication"
Control panel is out of
contact with controller
Wires to be checked.
Control panel to be checked.
Controller to be checked.
LED display is out of
order
No contact with controller.
Wires are damaged.
LED display is out of order
Wires to be checked.
LED display to be checked.
LED to be replaced.
Continuous sound
signal when turnstile
is open
Infrared sensors don’t
see
each other.
Infrared sensors are out of
order.
Plexiglas to be cleaned from dust.
Infrared sensors to be checked.
Infrared sensors to be replaced if they
are out of order.
The wing stays in half
opened position.
Magnetic sensor is out of
order.
Mechanism jamming.
Blade opening to be checked manually
turning off power supply.
Mechanism components to be
checked.
Sensor adjustment to be checked.
The wing stay open
Magnetic sensor is out of
order.
Mechanism jamming
“FREE ACCESS” mode is
set.
Infrared sensors are out of
order
Blade opening to be checked manually
turning off power supply.
Mechanism components to be
checked.
Sensor adjustment to be checked
The wing opens slowly
Mechanism jamming.
Infrared sensors don’t see
each other.
Infrared sensors are out of
order.
Magnetic sensor to be
checked.
Check manually whether it operates or
not. Mechanism components to be
checked. Magnetic sensor to be
adjusted or PCB to be replaced
Magnetic sensor to be adjusted or PCB
to be replaced.
Wires to be checked.
4.3. «JETPAN-1» turnstile blade initialization procedure
Initial setting of the blade zero position at the first activation of the turnstile:
1)
Turn OFF the power supply;
2)
Motor to be disconnected from PCB 201terminal: MOT1 (Fig.7);
3)
Blade to be set in the required zero position (Fig.20);