8
Continued Table 3
1
2
3
Altitude above sea level
up to 2000m
Environment
Explosion
-
proof, does not contain
current
-
conducting dust, aggressive
gases and vapours in concentration
destroying
isolation
and
metals,
disturbing normal operation of the
equipment installed in turnstiles
Installation site
In enclosed spaces in the absence of
direct impact of precipitations and solar
radiation
Operating position
Vertical,
deviation
from
vertical
position no more than 1º to any side is
allowed
1.1.5 Reliability indices:
−
mean time to repair (without delivery time of spare parts, tools and accessories) – at
most 6 hours;
−
mean time to failure – at least 1 500 000 accesses;
−
mean service life between overhauls – at least 10 years
1.2 Specifications
Key parameters of the turnstile are specified in Table 4.
Table 4
Parameter description
Unit measure
Parameter
value
Traffic flow capacity in free access mode, at least
man/min.
30
Opening/closing time
s
0,8
Maximum access way width
mm
500
Power supply voltage
–
AC power supply (primary)
V
Hz
~ 100
240
50/60
–
DC power supply (secondary)
V
12
Maximum power consumption
W
155
Index of protection according to EN 60529
-
IP41
1.3 Configuration and Scope of Delivery
1.3.1 The turnstile modification
depends on the number of access ways:
1) For arrangement of single access way the turnstile «JETPAN-1» " is a set of two similar in
design pedestrian gates (Master and Slave) with one each of which has one glass leaf (reference
designation Т3.КСD.ХK))