12 AUIA.123.00.00.00.00-05 OM
Voltage of logical «1»
(3 5)V
Voltage of logical «0»
(0 2,2)V
Maximum peak voltage supplied to the inputs «INP1» ÷ «INP5»
15V
Peak voltage switched by transistors of signal outputs
50V
Peak current switched through signal outputs
0,1А
Power supply voltage of controller
(9 15)V
Peak consumption current
0,15А
Number of signal reception and transmission serial ports (RS-485)
1
Climatic version and category of location according to the GOST 15150-69
NF4
Figure 3 – Appearance of the controller РСВ.112.21.20.00
1.8.2.3 Description of operation
The controller РСВ.112.21.20.00 operates according to the program fed into the microprocessor
memory. The turnstile's mechanism motor controller and LED displays
1
are controlled according to
control commands and status of rotor position sensors based on the logic entered into the program.
Control commands can be transmitted via RS-485 (from control panel) or logical inputs (by closing
and opening of inputs «INP1» ÷ «INP5» on «GND»).
Controller (along with the turnstile) can be in the «INITIAL STATE» (closed for access) or in the
following access modes: