19 AUIA.123.00.00.00.00-05 OM
* In this case other control panel buttons of single and free access in chosen direction are
locked
** In this case all control panel buttons of single and free access in both directions are locked
2.3.2.3 The turnstile is ready for long-term operation.
2.4 Contingency actions
For emergency evacuation of people (in case of fire, acts of God etc.) and providing of free access the
turnstile must be unlocked from control panel by sending the relevant command.
3 MAINTENANCE
3.1 General instructions
3.1.1 Commissioning and subsequent maintenance of the turnstile should be performed only by the
staff to be in charge of the turnstile.
3.1.2 The turnstile can be serviced only by the staff having the relevant electrical safety qualification
level according to the national requirements.
3.1.3 The turnstile can be installed and operated only by the qualified safety instructed staff having the
relevant class of permit to work with electrical facilities with voltage up to 1000V, awaring of this
OM, design and the turnstile’s principle of operation.
3.2 Safety Measures
3.2.1 During maintenance of the turnstile the relevant safety measures, specified in p. 2.1, must be
observed.
IT
IS
FORBIDDEN
TO
USE
DEFECTIVE
APPLIANCES,
TOOLS,
FUSES,
INSTRUMENTATION SERVICE LIFE OF WHICH EXPIRED. MEASURING DEVICES,
WHICH TERM OF CHECKING HAS ENDED
3.2.2 When instrumentations are prepared for operation it is necessary to comply with the safety
requirements specified in instrumentation instruction manuals.
3.3 Maintenance procedure
3.3.1 Maintenance of the turnstile includes preventive measures which are taken according to
established frequency to maintain the turnstile in operational condition, decreasing of component
wearing and prevention of faults and malfunctions.
3.3.2 Daily and periodic maintenance of the turnstile are recommended.
Normally the daily maintenance is carried out before the beginning of work or during operational
timeout and includes visual inspection of the turnstile's housing, and, if required, mechanical
troubleshooting, elimination of corrosion and pollution from the surface.
IT
IS
FORBIDDEN
TO
USE
DEFECTIVE
APPLIANCES,
TOOLS,
FUSES,
INSTRUMENTATION SERVICE LIFE OF WHICH EXPIRED. MEASURING DEVICES,
WHICH TERM OF CHECKING HAS ENDED
3.3.3 Periodic maintenance is performed at least twice a year and includes as follows:
–
visual inspection of the turnstile's housing, control mechanism and other components for absence
of corrosion, warps and other mechanical defects and pollutions;
–
visual inspection of power and connection cables’ condition as well as earthing;
–
verification of the turnstile's performance during manual control in the modes specified in the
Table 9 or as part of access control system using cards and badges;
–
checking of reliability of tightness of the turnstile's screw joints.